Technical data

88..00 FFLLUUEE OOPPTTIIOONNSS
1188
© Dimple
x Boiler
s 2008
88..55 KKiitt CC HHoorriizzoonnttaall AAnnttii--PPlluummee FFlluuee KKiitt
((CC1133)) -- PPaarrtt NNoo.. 995566008844
This kit is recommended if the condensate plume from the flue
may cause a nui
sance or affect the surroundings. The air inlet
remains outside and the flue duct is routed separately using a
60mm duct enclosed by a protective 80mm tube. To calculate
the maximum lengths of 60/100 concentric flue and 60mm
flue ducts, use the table below.
For installation details refer to the flue kit instructions.
Dimensions from vertical terminals to opening windows should
be in line with Fig. 19.
(For use with Standard horizontal telescopic flue kit - Part no.
956120 - only).
This kit is useful for deflecting the condensate plume away
from walls or boundaries. It should only be used to deflect the
condensate plume left or right.
60/100mm concentric vertical flue system.
Maximum length = 12m. The flue kit contains two additional
45° elbows and 2.5 metres of 60/100 concentric ducts as well
as a special wall bracket to pass the guttering (see Fig. 26).
The conc
en
t
ric
flu
e will be routed vertically alongside the
outside wall to above the roofline. Special seals are required to
prevent rainwater penetrating the pipe joints.
F
or installation details refer to the flue kit instructions.
88..66 PPlluummee DDiivveerrtteerr TTeerrmmiinnaall KKiitt
PPaarrtt NNoo.. 995566110033
88..77 KKiitt DD EExxtteerrnnaall VVeerrttiiccaall FFlluuee
((CC3333)) -- PPaarrtt nnoo.. 995566008855
9
3 flanged elbow (concentric)
w
ith sampling point
R
aised external flue outlet kit -
Part no. 956084
Kit C
Raised Ø60mm flue
outlet duct with
Ø
80mm anti-freeze
pipe.
Max height of raised
flue from top of boiler
to centre of outlet 8.5m
M
in height 1m.
93 flanged elbow (concentric)
with sampling point
Max. lengths (from top of
boiler to AIR COWL 12m
Min. length 1m.
Kit D
Ø60/100mm concentric
air/flue pipe -
Part no. 956093
(1m extension)
and
Part no, 956092
(0.5m extension)
For outside installations
the pipe joints have to
be covered with special
“lip-seal” to prevent
rain ingress.
Ensure all horizontally fitted
pipes are routed with a
1.5-3° fall towards the boiler.
External vertical flue kit - Part no. 956085
Roof terminal
with rain cover.
88..44 TToottaall EEqquuiivvaalleenntt LLeennggtthhss ffoorr CCoonncceennttrriicc
((6600//110000mmmm)) fflluuee ssyysstteemmss
FFiigg.. 2244
FFiigg.. 2233
FFiigg.. 2255
FFiigg.. 2266
CCoommppoonneenntt
45° Bend
93° Bend
0.5m Extension
1.0m Extension
Support Bracket
EEqquuiivvaalleenntt lleennggtthh iinn mmeettrreess
0.5m
1.0m
0.5m
1.0m
N/A
PPaarrtt nnuummbbeerr
956090 - 2 off
956091
956092
956093
840517
CCoonncceennttrriicc ((6600//110000mmmm))
fflluuee lleennggtthh ((mmeettrreess))
00..33 00..55
4455°° BBeenndd
11..00 11..55 22..00 22..55 33..00 33..55 44..00 44..55 55..00
MMaaxxiimmuumm ((6600//8800mmmm)) fflluuee
lleennggtthh aalllloowweedd ((mmeettrreess))
99..22
EExxaammppllee:: IIff rreeqquuiirreedd lleennggtthh ooff 6600//110000mmmm ccoonncceennttrriicc == 11mm
tthheenn mmaaxxiimmuumm 6600//8800 lleennggtthh == 88..55mm
99..00 88..55 88 77..55 77 66..55 66 55..55 55 44..55
SSuuppppoorrtt BBrraacckkeett
9933°° BBeenndd
00..55mm EExxtteennssiioonn
11..00mm EExxtteennssiioonn