Technical data
88..00 FFLLUUEE OOPPTTIIOONNSS
© Dimple
x Boiler
s 2008
1199
88..88 KKiitt EE CChhiimmnneeyy FFlluuee LLiinneerr KKiitt
((BB2233)) -- PPaarrtt nnoo.. 995566008822
NNoottee::
Dimplex System 18 and 30: Maximum flue length = 30m.
Minimum length for all Dimplex System boilers = 5m.
This kit is suitable for open flue application in accordance with
BS5440 parts 1 & 2 where a room sealed flue installation is
impractical. The kit comprises of a flue adaptor from the
appliance to the chimney, a flexible plastic flue liner with
connection parts and chimney terminal (see Fig. 27). Further
guidance on ventilation requirements is given in section 7.3.
See ‘Total equivalent lengths for concentric (60/100mm) flue
systems’
88..1100 KKiitt FF:: TTwwiinn FFlluuee SSyysstteemm
((CC5533)) -- PPaarrtt nnoo.. 995566008800
NNoottee::
Maximum flue length (air duct + flue duct) = 38m.
Minimum
flue length (air duct + flue duct) = 10m.
The kit
compri
ses of a twin adapt
or suitable for 80mm ducts,
from which the air intake is taken from the adjacent outside
wall (see Fig. 28) and the flue duct is routed vertically through
the roof.
It
i
s
nnoott
r
ecommended t
o r
out
e the
flue duct through living
spac
e areas, i.e. bedrooms, living rooms etc.
For installation details refer to the instructions provided with
the twin flued kit.
Centralising brackets
Chimney terminal
93 flanged elbow (concentric)
with sampling point
Ø60/100mm concentric
chimney adaptor pipe.
T
he chimney must be swept
a
nd cleared of any debris
a
nd obstructions.
Chimney
p
late
Flexible corrugated plastic flue liner
Ø80mm according to EN 14471
Max. length 30m.
Min. length 5m.
KIT E
Chimney flue liner kit - Part no. 956082
Ø80mm air intake
Split flue system
Roof terminal with pitched
roof flashing kit.
If the flue pipe passes
through compartment
from wall/floors, the
requirements set out
in Building Regulations
Part B must be followe
d.
Ø80mm twin adaptor
with sampling point.
If the flue pipe are boxed in then
access must be provided to inspect
the flue ducts during installation
and subsequent service visits.
The access panels and flue boxing
should be sealed from the room.
Split pipe vertical
flue outlet kit -
Part no. 956080
Kit F
FFiigg.. 2277
FFiigg.. 2288
CCoommppoonneenntt
90° Bend
45° Bend
1.0m Extension
2.0m Extension
EEqquuiivvaalleenntt lleennggtthh iinn mmeettrreess
AAiirr DDuucctt
4.0m
2.0m
1.0m
2.0m
FFlluuee DDuucctt
8.0m
4.0m
2.0m
4.0m
PPaarrtt nnuummbbeerr
956100
956099
956101
956102
88..99 KKiitt EE:: KKeeyy fflluuee ddiimmeennssiioonnss ++ AAcccceessssoorriieess
Minimum length 60/100mm horizontal flue 100mm From boiler to chimney
Maximum length 60/100mm horizontal flue 2000mm From boiler to chimney
Minimum length 60/100mm vertical flue 200mm From boiler to chimney
Maximum length 60/100mm vertical flue 2000mm From boiler to chimney
Minimum length 80mm flue liner 5000mm From adaptor to chimney terminal
Maximum length 80mm flu
e liner
30000mm
From adaptor to chimney terminal
A
A
c
c
c
c
e
e
s
s
s
s
o
o
r
r
y
y
L
L
e
e
n
n
g
g
t
t
h
h
P
P
a
a
r
r
t
t
N
N
u
u
m
m
b
b
e
e
r
r
80mm Fle
xitube
flue liner 10m 956110
80mm Flexitube flue liner 20m 956111
80mm Flexitube flu
e liner 30m 956112
Boiler vertical flue adaptor/turret socket N/A 956087