Instructions / Assembly
8 www.dimplex.com
WARNING: The Convex
In Stud replace is wall
mountable and can be built in
a wall space 16 inches (406
mm) over-center between 2”
x 4” wall studs. Follow the
installation instructions for
either wall mount or built-in
mounting; failure to do so may
cause damage or injury.
Wall Mounting Instructions
Leave the glass assembly 1.
uninstalled until step 10.
Select a location for the 2.
replace, preferably above
an electrical outlet and there
must be at least one wall stud
behind for the replace to
mount onto. The bottom of
the unit must be a minimum
of 14" (356 mm) above the
oor (mounting holes 29¾"
(0.75 m) minimum above the
oor) (Figure 2).
Access to the electrical outlet
must be maintained. Ensure the
installation meets the national and
state/provincial electrical codes.
!
NOTE: It is recommended
that the bottom of the unit not be
mounted higher than 48" (1.22
m) from the ground to maintain
an optimized viewing angle of the
Fireplace Installation
ame.
CAUTION: The replace must
be mounted at two (2) points, one
of which must be on a wall stud.
WARNING: High tempera-
tures may be generated under
certain abnormal conditions. Do
not partially or fully cover or ob-
struct the bottom of this heater.
Bottom of unit must be a mini-
mum of 14" (356 mm) above the
oor or any surface such as a ta-
bletop to ensure adequate space
Figure 2
A
B C D E F G
H
29¾” - 75¾”
(0.75 - 1.92m)
14” - 48”
(0.36 - 1.22m)