Table 1 - Dimensions A B C D E F G H I J K
Bellingham 5kw 596 466 35 233 120 368 70 140 195 465 127
Note: All Dimensions in mm. Dimensions stated may be subject to a slight ± variation. ( 25.4mm = 1”)
Table 2 - Technical Specication Bellingham 5kw
Nominal heat output
Wood kW 5.0
Solid Fuel (Ancit) kW 4.9
Efciency
Wood % 84.3
Solid Fuel (Ancit) % 85.0
CO Emission (@13% O2)
Wood % 0.34
Solid Fuel (Ancit) % 0.27
Flue Gas Temp
Wood °C 210
Solid Fuel (Ancit) °C 215
Flue Gas Mass Flow
Wood g/s 3.4
Solid Fuel (Ancit) g/s 2.9
Refuel Period hr 1
Safe Distance to Combustibles mm see table 5
Flue Outlet Size mm / inch 127 / 5
Product Weight kg 71.8
Additional Room Ventillation Required cm² see table 4
2
A
B
D
E
C
J
H
F
K (Dia)
I
G