Operating instructions
E-10
English
6.1
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active for a dynamic cooling block.
N
T1
T2
Y
Cooling function
Dyn. cooling
Has the system got silent (dew point-controlled)
cooling?
Yes
No
Cooling function
Sets the room set temperature for silent cooling
The actual value is measured by room climate
control station 1
15 °C
... 20 °C...
30 °C
Cooling function
Silent cooling
Rise in the minimum flow temperature
calculated from the measured values from the
room climate control station during silent
cooling. A raised value reduces the risk that
condensate will form.
1.5 K
... 2.0 K ...
5.0 K
Cooling function
Silent cooling
Setting of the external temperature below
which the cooling operation is terminated in the
case of reversible HPs.
-10.0 °C
... 15.0 °C ...
35.0 °C
Cooling function
Sets DHW preparation Domestic hot water
Sensor
The hysteresis of the hot water set temperature
forms the neutral zone below which a request
for domestic hot water will be issued.
2 K
...
15 K
Domestic hot water
Sensor
Sets the desired hot water temperature 30 °C
... 45 °C ...
85 °C
Domestic hot water
Sensor
Sets the time programs for hot water blocks Domestic hot water
Sensor
Sets the times in which DHW preparation is
blocked
00:00
...
23:59
Domestic hot water
Sensor
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is
lowered. Operations to lower the temperature
that exceed a weekday are activated or
deactivated at the end of each day accordingly.
N
T1
T2
Y
Domestic hot water
Sensor
Thermal disinfection is executed via the flange
heater at the set start time. The heating period
is terminated automatically when the set
temperature is reached or after 4 hours at the
latest.
Domestic hot water
Sensor
Flange heater
System-specific parameters
Setting range Display