Owner`s manual

1
3
V. cleans
First according to the "pressure relief steps" to eject the pressure and coating inside
equipment.
Nozzles and nozzle jacket will be unloaded.
Add suction pipe will be put into clear water bucket or the appropriation dilution.
Put the reflux tube into Paint waste barrels.
Return valve will be installed in the vertical direction
Pressure control buttons will be set in the washing position
(the red area)
Turn on the power switch.
In the solvent recycling equipment, paint residues discharged until clean water or
solvent from the outflow of reflux tube.
Shut the power switch.
Return valve will be set in the horizontal position and open spray gun insurance.
turn on the power switch
Buttonning up the trigger makes solvents or clear water flush to remain coating inside high
pressure tube and spray gun, until solvents or clear water are jet from the muzzl
shut spray gun insurance.as the right chart
Loaded nozzle jacket and open spray gun insurance.
Nozzle will be reversed 180 degrees, sustained gun deduction 1 ~ 2 seconds (cleaning
nozzles), nozzles and nozzle jacket unloaded and cleaned with brushes.(cleaning
nozzle attention to put into a white-washers and nozzles Block, please donot lost.)
Unloading equipment and spray guns on the filter net then clean
Unload suction tube filter and clean .
With piles of rags solvent or clean water equipment, high-pressure hoses and spray
gun all the components of the appearance wipe clean until a surface Adhesion without
coating.
Equipment in the infusion fluid valve 5-6 PSL drop of a closed yellow liquid.
Equipment will be stored in dry, clean and well-ventilated places