User Manual

Table Of Contents
User Manual
10-24V DC
Idle Current
45mA
Active Current 80mA
Waterproof
IP67
1500
Card type
13.56MHz
2A
6cm
500mA
100*70mm,100
INTRODUCTION
Features and Benefits
Specifications
User Capacity
Mifare (UID 7 bytes, 4 byets, Plus)
Frequency
Wiegand Interface
Operating Temperature
Card: Wiegand 26 bits or 34 bits,
PIN: 4 bits
Lock Output Load
Alarm Output Load
Operating Humidity
10%98%RH
Dimensions
A7: L110x76x22mm
Unit Weight
A7: 445g, A8: 350g, A9: 175g
Shipping Weight
A7: 510g, A8: 412g, A9: 338g
Packing List
Add users
Delete users
Sound and Light Indication
Operation Status
LED
Buzzer
Red light shines
One beep
Red light bright
Orange light bright
Open lock
Green light bright
Operation failed
(Admin Code) #
*
*
INSTALLATION
Grey & Black
Yellow & Black
STANDALONE MODE
Connection Diagram
Special Power Supply for Access Control
(Admin Code) #
*
(Admin Code) #
*
*
*
*
Programming Step
Programming Step
Keystroke Combination
Keystroke Combination
Enter Program Mode
Enter Program Mode
(Factory default is 777777)
(Factory default is 777777)
Exit Program Mode
Exit Program Mode
Wiring
Wire Color
Function
Notes
Wiegand output/input Data0
Wiegand output/input Data1
D1
White
Green
D0
Alarm Negative
ALARM-
Grey
Grey & Black
Grey & Black
Grey & Black
Brown
D_IN
Door Contact
Yellow
Yellow & Black
Yellow & Black
Yellow & Black
OPEN
Request to Exit Button
10-24V DC Power Input
Red
DC+
Black
GND
Negative Pole
Blue
NO
Relay NO
Relay COM
COM
Purple
Orange
NC
Relay NC
BELL
BELL
External BELL
External BELL
Outdoor
Indoor
Simplified Instruction
Function Description
Operation
Enter the Programming Mode
then you can do the programming
(777777 is the factory
default Admin code)
Change the Admin Code
0 - New Code - # - Repeat the
New Code - #
(code:6 digits)
Add Card User
1 - Read Card - #
(can add Cards continuously)
Add PIN User
1- User ID# - PIN- #
(ID number:1-1500)
(ID number:1-1500)
Delete User
2 - Read Card - # for Card User
2 - User ID - # for PIN or Card User
Exit from the Programming Mode
How to release the door
-40°C+70°C,(-40°F~+158°F)
Adm in Add Ca rd Adm in Dele te Card
Admin Car ds
Diode 1N4 004
(For rela y circu it protection)
Wal l Anchors
Screw Drive r
Self Tapping Screws
Modify Admin Code
0 (New Admin Code) #
(Repeat New Admin Code) #
Add/Delete Users by Admin Cards (in standby mode)
Step 1: Read Admin Add Card
Step 2: Read user cards
(Repeat step 2 for additional user cards)
Step 3: Read Admin Add Card again to end
Step 1: Read Admin Delete Card)
Step 2: Read user cards
(Repeat step 2 for additional user cards)
Step 3: Read Admin Delete Card again to end
Red shines
Red bright
Doorbell Wiring
WIEGAND READER MODE
Orange
bright
(Admin Code) #
*
Programming Step Keystroke Combination
Enter Program Mode
Add Card User
Add Card: By Card
Add Card: By ID
Add Card: By Card
number
number
1 (Read Card) #
LED
1 (Input ID number) # (Read
Card)
Red shines
Orange
bright
Read Range
Open door by card
Open door by User PIN
Open door by user card + PIN
(Read Card)
(Users PIN) #
(Read Card) (Users PIN) #
Stand-alone Access Control/Reader
This product is a Keypad standalone access control. 1500 user
capacity and supporting 13.56MHz Mifare card (UID 7 bytes,
4 byets, Plus). It can be access by card, PIN, card + PIN. It also
equipped with admin add/delete cards, door detection, external
alarm and Wiegand input/output interface.
Waterproof, conforms to IP67
With Wiegand input & output, it can be used as not only
standalone, but also slave reader or access controller.
Equipped with admin cards, which can add/delete users quickly.
Pulse Mode or Toggle Mode
Door Bell button (A8,A9)
Operating Voltage
1. Remove the back cover from the unit with screw.
2. Drill hole on the wall according to the back size of the machine
and fix the back cover on the wall.
3. Thread the cable through cable hole, connect related cable. For
the un-used cable please separate with insulating tape.
4. After wiring, install front casing and fix the back cover well with
screws.
Stand by Mode
Enter program Mode
In the Program Mode
Three beeps
Modify Admin Code
LED
Note: Admin should enter Program Mode, then the settings can be
set or reset. For security, you must change the Admin Code and then
keep in mind.
Factory Default Setting and Add Admin Cards
power off, press exit button , power on, release it until hear two
beeps, then the red LED will be orange. It means the device is under
the status of waiting for adding admin cards. Swiping two cards, the
first card is “Admin Add Card, the second card is “Admin Delete
Card”, then standby mode and the red light bright. the device will be in
Resets to factory default setting and adding admin cards are
successful.
If you don't need to add admin cards: Press “ ”, power on, hold it for
more than 10 seconds.
Note: Reset to factory default, the users' information won't be
deleted.
DC+
D_IN
OPEN
ALARM-
D0
BELL
BELL
BELL
BELL
D1
GND
COM
NC
NO
+
+
-
-
DC power Supply for Access Control
DC+
D_IN
OPEN
ALARM-
D0
D1
GND
COM
NC
NO
+
-
10-24V DC
Relay N O
Relay C OM
Relay N C
-
+
1N4 004
1N4 004
Note: The electric locks must be connected with diode(1N4004),
otherwise the device might be damaged. The white end of the diode
is connected to positive pole of electric lock and the other end is
connected to negative pole of the electric lock.
Enter and Exit Program Mode
Add Users (ID number: 1-1500)
OR
OR
Red bright
Red bright
Red bright
Red bright
(Admin Code) #
*
(Admin Code) #
*
(Admin Code) #
*
(Admin Code) #
*
Programming Step
Programming Step
Programming Step
Programming Step
Keystroke Combination
Keystroke Combination
Keystroke Combination
Keystroke Combination
Enter Program Mode
Enter Program Mode
Enter Program Mode
Enter Program Mode
LED
LED
LED
LED
Red shines
Red shines
Red shines
Red shines
Exit Program Mode
Exit Program Mode
Exit Program Mode
Exit Program Mode
Orange
bright
Orange
bright
*
*
*
*
*
*
*
*
*
*
Add PIN users
Add PIN User
1 (Input ID number) #
(4-6 digits PIN) #...
Red bright
Red bright
Red bright
Red bright
Orange bright
(Admin Code) #
*
(Admin Code) #
*
(Admin Code) #
*
Programming Step
Programming Step
Programming Step
Keystroke Combination
Keystroke Combination
Keystroke Combination
Enter Program Mode
Enter Program Mode
Enter Program Mode
LED
LED
LED
Red shines
Red shines
Red shines
OR
OR
Exit Program Mode
Exit Program Mode
Exit Program Mode
Exit Program Mode
Note: 1. When swiping cards to add users, the ID number is from
small to big.
2. When adding card users, an attached PIN 1234 will be
added in automatically. This PIN cannot be used to open
door. If you want to open door by card + PIN, you should
first change the old PIN 1234, method referring to Change
PIN.
Delete Users
Delete Card: By Card
Delete Card: By ID
Delete Card: By Card
number
number
2 (Read Card) #
2 (Input ID number) #
Delete All User
2 0000 #
Orange bright
Orange bright
Orange bright
Orange bright
Orange bright
Orange bright
*
Red bright
Orange
bright
(Admin Code) #
*
Programming Step Keystroke Combination
Enter Program Mode
LED
Red shines
Exit Program Mode
Access Mode Setting
OR
Open door by card + PIN
OR
Open door only by card
Open door by card or PIN
4 2 # (Factory default)
4 1 #
4 0 #
Access Time Setting
Add anti-duress users (1501-1510)
Time Setting
Add anti-duress Card
Set Toggle Mode
Add anti-duress PIN
3 (1-99) #
7 (Read Card)
3 9999 #
7 ID# (4-6 digits PIN)#
Note: 1. Access time range: 1-99 seconds, factory default is 5
seconds.
2. Pulse Mode and Toggle Mode, you can only choose one.
3. Pulse Mode: The door will be closed automatically after
opening the door for a while.
Toggle Mode: Under this mode, after opening the door, the
door won't be closed automatically until next valid user
input. Whether open or close the door, you must swipe valid
card or input valid PIN.
Door Detection Setting
To enable door detection
To disable door detection
5 0 # (Factory Default)
5 1 #
Note: After enable the door detection function, you must connect
the detection switch into the wiring. There will be two
detection status:
1. The door is opened by valid user, but not closed in 1 minute,
the device will beep.
How to stop the warnings: Close the door/valid user/
Automatically stop when the alarm time is up.
2. If the door opened by force, the device and external alarm
will activate.
How to stop the alarm: Valid user/Automatically stop when
the alarm time is up.
Safe Mode Setting
Close safe mode
Lockout mode
Alarm mode
6 0 # (Factory default)
6 1 #
6 2 #
Note: Lockout mode: If swipe card/input PIN with invalid users for
10 times in 1 minute, the device will be lockout for 10 minutes.
Alarm Output: If swipe card/input PIN with invalid users for
10 times in 1 minute, the device will alarm.
Alarm output time setting (factory default is 1 minute)
Set Wiegand Output Formats of Card
Time Setting
Wiegand 34
Wiegand 26
8 (0-3) #
9 0 # (Factory default)
9 1 #
Orange bright
Orange bright
Orange bright
Note: Alarm time range: 0-3 minutes
Connection Diagram
White
Green
Red
Black
Controller
DC +
GND
DO
D1
Reader
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
*
*
#
#
Note: When the device is used as salve reader, the Wiegand output
format of the card is 26 bits or 34 bits; the format of PIN is 4 bits
output.
User Operation
Change PIN
Programming Step
Programming Step
Keystroke Combination
Keystroke Combination
Change independent PIN
(ID number) (old PIN) # (New PIN) #
(Repeat New PIN) #
Change PIN which
attached to the card users
(Read Card) # (old PIN) #
(New PIN) # (Repeat New PIN) #
Note: The PIN cannot be “1234, and the PIN attached to the card is
only used for card+ PIN access mode.
How to Release the Door
Open door by r card
OR
Open by PIN
OR
Open door by card + PIN
(Read Card)
(Input PIN) #
(Read Card) (Input PIN) #
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
*
*
#
#
1 2
3
4
5
6
7 8
9 0
*
#
1
2
3
4
5
6
7 8
9 0
*
#
A7 A8 A9
A7,A8 Zinc-alloy housing, A9 ABS shell
A8: L129x44x20
A9: L134xW48xH25mm
80mm
60mm
40mm
Φ9mm
82.8mm
60mm
102
mm
1 (Input 8/10 digits Card
number)#
2 (Input 8/10 digits Card
number)#
Note: If under threat, swiping the Anti-duress card or input
Anti-duress PIN, the door will open, but the external alarm will
activate to inform your friend to help you.
01 02 03 04 05 06
07 08 09 10 11 12