INSTALLATION GUIDE
1 OF 2
MATTONE
™
DIRECT-WIRE LED STEP LIGHT FIXTURE
®
Read all warnings and installaon instrucons thoroughly.
WARNING
Safety & Warnings
• Install in accordance with the Naonal Electric Code, and local
regulaons.
• This product is intended to be installed and serviced by a qualied,
licensed electrician.
• This product is IP65 rated for outdoor applicaons when installed with
MATTONE Support Housing (housing box sold separately).
• Ensure applicable wire is installed between driver, xture, and any
controls in between. When choosing wire, factor in voltage drop,
amperage rang, and type (in-wall rated, wet locaon rated, etc.).
Inadequate wire installaon could overheat wires, and cause a re.
• The MATTONE Support Housing must be grounded. Ensure to aach
earth ground to the MATTONE Support Housing.
• Do not install this product in an environment outside the listed ambient
temperature.
• Do not modify or disassemble this product beyond instrucons or the
warranty will be void.
1. Turn o 120-277VAC power at circuit breaker.
2. Mount MATTONE Support Housing (DI-MATB-HOUS) to studs with
MATTONE Mounng Brackets (DI-MATB-HANG).
3. Pull main power cable through MATTONE Support Housing and aach
earth Ground to housing chassis.
4. Aach AC Hot to MATTONE light engine Hot (black). Aach AC Neutral
to light engine Neutral (white).
5. Insert light engine into support housing and aach faceplate with
included Allen screws (use included #3 Allen key).
6. Turn on 120-277VAC power at circuit breaker.
Input Voltage 100-277VAC, 50/60Hz
Power Consumpon 3W / .025A
Ambient Temperature -4° ~ 122°F (-20° ~ 50°C)
For full specicaons, see the ‘Specicaon Sheet’ available at the online
product page.
Environment Outdoor / wet locaon / IP65
Mounng
Mounts in the MATTONE Support Housing
(sold separately). Support Housing can be
installed with the MATTONE Mounng
Brackets (also sold separately).
Cercaons
cULus Listed (USA & Canada) Surface
Mount Luminaire, UL # E336778.
Quick Specs
IG100214-1.2
Installation
Install in accordance with the NEC and local regulaons.
See next page for wiring and mounng diagram.
120V
AC
Dry/Wet Location
WARNING
Shock Hazard. May result in serious injury or death.