Owner's manual

IG051514-1.0
1.877.817.6028
www.DiodeLED.com
INSTALLATION GUIDE
®
info@DiodeLED.com www.DiodeLED.com
1 OF 3
RGB WALL MOUNT COLOR CONTROLLER
Install in accordance with the Naonal Electric Code, and local
regulaons.
This product is intended to be installed and serviced by a qualied,
licensed electrician.
Do not connect directly to high voltage 120V~277V power. Install with
a compable Class 2 constant voltage LED driver (power supply).
Only install compable LED drivers and xtures. Contact technical
support or visit the product page for compable products.
This product is rated for indoor installaon and is not protected against
moisture.
Proper heat dissipaon will prolong the working lifespan of this product.
Install in a well-venlated area free from explosive gases and vapors.
Ensure applicable wire is installed between driver, xture, and any
controls in between. When choosing wire, factor in voltage drop,
amperage rang, and type (in-wall rated, wet locaon rated, etc.).
Inadequate wire installaon could overhead wires, and cause a re.
Do not modify or disassemble this product beyond instrucons or the
warranty will be void.
Safety & Warnings
Prior to installaon, verify all components are a compable system. Congure and pre-test your LED system prior to permanent installaon to ensure all
components are operang correctly. Install in accordance with the NEC and local regulaons.
Installation
Quick Specs
Ambient Temperature † -4° ~ 122°F (-20° ~ 50°C)
Transming Distance 130 .
Control Type
Pulse Width Modulaon (PWM).
3-channel RGB xtures.
Input / Output Voltage 12-24VDC constant voltage
Max Current Load 3A x 3CH Max 9A
Max Output Power
108W/216W (12V/24V)
Environment Indoor / dry locaon
Do not install product in an environment outside the listed ambient
temperature.
Turn OFF High Voltage AC Power at the main breaker.
Determine Locaons to Install 3 Main Components.
Refer to the ‘System Diagrams.
Mount RGB Receiver to Surface. See ‘Wiring Connecons’, use
applicable screws.
Aach Lighng Load and Driver. Only use copper wiring.
Reference ‘Wiring Connecons’ located further in guide for
visual. Use a mini athead screwdriver for aaching wires to
terminal ports. Terminals t up to 12AWG solid-core copper wire.
Verify a compable constant voltage driver is installed.
Install Addional Components, Verify Connecons, and Turn
Main Power ON at Breaker.
1
ON
OFFOFFOFF
ONON
OFFOFF
ONON
2
1) Driver 2) RGB Color
Controller
3) Fixture
Ensure applicable wire is installed between driver, xture, and any
controls in between. When choosing wire, factor in voltage drop,
amperage rang, and type (in-wall rated, wet locaon rated, etc.).
3
4
5
ON
OFFOFFOFF
ONON
OFFOFF
ONON
If system remains unresponsive or is working improperly, turn OFF
main power at breaker and verify all connecons. Review the ‘Wiring
Connecons.
DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER!
Read all warnings and installaon instrucons thoroughly.
WARNING
WARNING
Shock Hazard. May result in serious injury or death.
DO NOT CONNECT
TO HIGH VOLTAGE
Dry Location Only
12V
DC
24V
DC

Summary of content (3 pages)