Absolute Maximum Ratings (Notes 6, 7)
Symbol Description Rating Unit
ESD HBM Human Body Model ESD Protection 2 kV
ESD CDM Charged Device Model ESD Protection 1 kV
ESD MM Machine Model ESD Protection 200 V
V
CC
Supply Voltage Range -0.5 to 6.5 V
V
I
Input Voltage Range -0.5 to 6.5 V
V
O
Voltage Applied to Output in High Impedance or I
OFF
State
-0.5 to 6.5 V
V
O
Voltage Applied to Output in High or Low State.
-0.5 to V
CC
+0.5
V
I
IK
Input Clamp Current V
I
< 0
-50 mA
I
OK
Output Clamp Current -50 mA
I
O
Continuous Output Current ±50 mA
I
CC,
I
GN
Continuous Current Through V
CC
or GND
±100 mA
T
J
Operating Junction Temperature -40 to +150 °C
T
STG
Storage Temperature -65 to +150 °C
Notes: 6. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device
operation should be within recommend values.
7. Forcing the maximum allowed voltage could cause a condition exceeding the maximum current or conversely forcing the maximum current could
cause a condition exceeding the maximum voltage. The ratings of both current and voltage must be maintained within the controlled range..