User guide
100mA REGULATED CHARGE PUMP AP3602A/B
4
Dec. 2012 Rev. 2. 0 BCD Semiconductor Manufacturing Limited
Data Sheet
Note 1: Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to
the device. These are stress ratings only, and functional operation of the device at these or any other conditions
beyond those indicated under "Recommended Operating Conditions" is not implied. Exposure to "Absolute Max-
imum Ratings" for extended periods may affect device reliability.
Parameter Symbol Min Max Unit
Input Voltage
V
IN
AP3602A 2.7 5
V
AP3602B 2.7 4.5
Operating Temperature T
A
-40 85
o
C
Recommended Operating Conditions
Absolute Maximum Ratings (Note 1)
Parameter Symbol Value Unit
Input Voltage V
IN
7V
Output Voltage V
O
7V
SHDN
Pin Voltage V
SHDN
7V
Thermal Resistance (Junction to Ambient, no Heat sink) R
θJA
300
o
C/W
Operating Junction Temperature T
J
150
o
C
Storage Temperature Range T
STG
-65 to 150
o
C
Lead Temperature (Soldering, 10sec) T
LEAD
260
o
C
ESD (Human Body Model) 2000 V