Owner manual
LM2902/ LM2902A/ LM2904/ LM2904A
Document number: DS36780 Rev. 1 - 2
3 of 13
www.diodes.com
March 2014
© Diodes Incorporated
LM2902/ LM2902A/ LM2904/ LM2904A
Absolute Maximum Ratings (Note 4) (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter Rating Unit
V
CC
Supply Voltage ±18 or 36 V
V
ID
Differential Input Voltage 36 V
V
IN
Input Voltage -0.3 to +36 V
θ
JA
Package thermal impedance
(Note 5)
SO-8 TBD
°C/W
SO-14 TBD
TSSOP-14 TBD
θ
JC
Package thermal impedance
(Note 6)
SO-8 TBD
°C/W
SO-14 TBD
TSSOP-14 TBD
—
Output Short-Circuit to GND
(One Amplifier) (Note 7)
V
CC
≤ 15V and T
A
= +25℃
Continuous —
T
A
Operating Temperature Range -40 to +125 °C
T
J
Operating Junction Temperature +150 °C
T
ST
Storage Temperature Range -65 to +150 °C
ESD
Human Body Mode ESD Protection (Note 8) 300
V
Machine Mode ESD Protection 150
Notes: 4. Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only; functional
operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device reliability.
5. Maximum power dissipation is a function of T
J(max)
, θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient temperature is
P
D
= (T
J(max)
− T
A
)/θ
JA
. Operating at the absolute maximum T
J
of +150°C can affect reliability.
6.
Maximum power dissipation is a function of T
J(max)
, θ
JC
, and T
A
. The maximum allowable power dissipation at any allowable ambient temperature is
P
D
= (T
J(max)
− T
A
)/θ
JA
. Operating at the absolute maximum T
J
of +150°C can affect reliability.
7. Short circuits from outputs to V
CC
or ground can cause excessive heating and eventual destruction.
8. Human body model, 1.5kΩ in series with 100pF.