Owner's manual

LMV331/ LMV393
Document number: DS37022 Rev. 1 - 2
3 of 13
www.diodes.com
May 2014
© Diodes Incorporated
ADVANCED INFORMATION
LMV331/ LM
V
393
Electrical Characteristics (Notes 6 & 7) (@T
A
= +25°C, V
EE
= 0V, V
CM
= 0V and R
L
= 5.1K, unless otherwise specified.)
Symbol Parameter Test Conditions Min Typ Max Unit
2.7V DC Electrical Characteristics
V
OS
Input Offset Voltage 1.7 7 mV
TCV
OS
Input Offset Voltage Average Drift
T
A
= full range
5 µV/°C
I
B
Input Bias Current
10 250
nA
T
A
= full range
400
I
OS
Input Offset Current
5 50
nA
T
A
= full range
150
V
CM
Common-Mode Input Voltage Range -0.1 +2.0 V
V
SAT
Saturation Voltage
I
SINK
1mA
120 mV
I
O
Output Sink Current
V
O
1.5V
5 23 mA
I
OL
Output Leakage Current
0.003
µA
T
A
= full range
1
I
S
Supply Current
LMV331 40 100 µA
LMV393
(Both Comparators)
70 150 uA
2.7V AC Electrical Characteristics
t
PHL
Propagation delay high to low
Input overdrive= 10mV 1000 ns
Input overdrive= 100mV 350 ns
t
PLH
Propagation delay low to high
Input overdrive= 10mV 500 ns
Input overdrive= 100mV 400 ns
5V DC Electrical Characteristics
V
OS
Input Offset Voltage
1.7 7
mV
T
A
= full range
9
TCV
OS
Input Offset Voltage Average Drift
T
A
= full range
5 µV/°C
I
B
Input Bias Current
25 250
nA
T
A
= full range
400
I
OS
Input Offset Current
2 50 nA
T
A
= full range
150
V
CM
Common-Mode Input Voltage Range -0.1 4.2 V
A
V
Large Signal Differential Voltage Gain 20 50 V/mV
V
SAT
Saturation Voltage
I
SINK
4mA
200 400 mV
I
SINK
4mA, T
A
= full
range
700
I
O
Output Sink Current
V
O
1.5V
10 84 mA
I
OL
Output Leakage Current
0.003
µA
T
A
= full range
1
I
S
Supply Current
LMV331
60 120
µA
T
A
= full range
150
LMV393
(Both Comparators)
100 200
uA
T
A
=full range 250
5VAC Electrical Characteristics
t
PHL
Propagation delay high to low
Input overdrive = 10mV 600 ns
Input overdrive = 100mV 200 ns
t
PLH
Propagation delay low to high
Input overdrive = 10mV 450 ns
Input overdrive = 100mV 300 ns
Notes: 6. Typical values represent the most likely parametric norm as determined at the time of characterization. Actual typical values may vary over time and will
also depend on the application and configuration. The typical values are not tested and are not guaranteed on shipped production material.
7. All limits are guaranteed by testing or statistical analysis.