User guide

ISSUE 2 - JANUARY 2000
ZDS1009
Parameter Symbol Min Max Unit Conditions
Breakdown Voltage BV
Y1-X1
120 V
I
Y1
=100µA
Breakdown Voltage BV
X1-E1
-30 V I
X1
=-10mA
Breakdown Voltage BV
Y1-E3
30 V I
Y1
=10mA
Breakdown Voltage BV
E1-Y1
-12 V
I
E1
=-100µA
Breakdown Voltage BV
E2-Y1
-6 V
I
E2
=-100µA
Breakdown Voltage BV
E3-X1
12 V
I
E3
=100µA
Breakdown Voltage BV
E4-X1
6VI
E4
=100uA
Leakage I
Y1
50 nA V
Y1-X1
=100V
Leakage I
X1
-10
µA
V
X1-E1
=-30V, V
y1
=V
E1
Leakage I
Y1
10
µA
V
Y1-E3
=30V,V
X1
=V
E3
Leakage I
E1
-100 nA V
E1-Y1
=-8V
Leakage I
E2
-100 nA V
E2-Y1
=-4V
Leakage I
E3
100 nA V
E3-X1
=8V
Leakage I
E4
100 nA V
E4-X1
=4V
Input Voltage V
Y1-E2
-1.45 -1.65 V I
Y1
=-1A
Input Voltage V
Y1-E3
1.45 1.75 V I
Y1
=1A,V
X1
=V
Y1
Input Voltage V
X1-E1
-1.45 -1.75 V I
X1
=-1A,V
X1
=V
Y1
Input Voltage V
X1-E4
1.45 1.65 V I
X1
=1A
Transfer
Characteristic
V
OUT
0.99 1.01 V See Fig 1.V
CC
=5V
R1=R3=R4=100,V
IN
=1V
Transfer
Characteristic
V
OUT
1 mV See Fig 1.V
CC
=5V
R1=R3=R4=100,V
IN
=5mV
Output Zero-Offset
Voltage
V
OFFSET
4mV
See Fig 2.V
CC
=5V,R
2
<1
R1=R3=R4=100
ABSOLUTE MAXIMUM RATINGS.
PARAMETER SYMBOL VALUE UNIT
Maximum Operating Voltage V
y1-x1
120 V
Maximum Voltage (E1-E2,E3-E4) V
E-E’
10 V
Peak Pulse Current I
M
4A
Continuous Current (E1-E4,E2-E3) I
C
1A
Total Power Dissipation at T
amb
= 25°C* P
tot
2W
Operating and Storage Temperature Range T
j
:T
stg
-55 to +150 °C
* The power which can bedissipated assuming thedevice is mountedin a typical manneron a PCBwith copper
equal to 2 inches square.
ELECTRICAL CHARACTERISTICS (at T
amb
=25°C)
2