Instructions / Assembly

HOTSURFACEIGNITERFITTINGINSTRUCTIONS
FittingInstructions
Pleasereadalltheseinstructionstotheendcarefullybeforebeginning
installation.
1.Identifywhichtypeofhotsurfaceigniterisinsideyourappliance.
2.Unplugyourexistingigniter,retainingallfittings,andmatchitup
withdiagramsabove(thiscanalsobedonebycomparingthetopend
viewofthebasetype).
3.Comparethepositionoftheridgeonyourexistingignitercarefully
tothetopviewdiagram.Ensurethatyouhavethecorrectignitertype.
Takeyourtimetoidentifythiscarefully.
4.Referringtothecentrebottomdiagram,breakoffthetabs
indicated,preferablywiththinnosepliers.
5.Cutofftheplugfromyourappliance,asclosetotheplugas
possible.Makesurethereisenoughleadtoworkwith.Bareone
quarterofaninchofwire.
6.Fittheuniversaladaptortotheapplianceusingexistingscrews.
Oncetheuniversaladaptorisfitted,screwtheigniterintotheadaptor,
asperthefinaldiagram,usingthescrewprovided.
7.Attachthewiresfromtheapplianceontotheigniter,bytwistingthe
baredendstogether,matchingonewirefromtheigniter,toonewire
fromthecontroller(pleaserefertodiagram).
8.Finally,taketheterminalcapsprovidedandscrewdowntightover
thejoinedbarewires,ensuringthatnobarewiresareshowing.If
necessary,theigniterwirescanbecuttolength.
9.Checkinstallationissecureandsafe,routingleadsawayfromthe
burner.
Commissioning
1.Turnonthegassupplyandelectricalsupplytotheappliance.
2.Settheroomthermostatforheat.
3.Testfurnaceforproperignitionandoperation.
4.VerifythatthePower‐OnLED,onthepowermodule,isonduring
theGlo‐Stix™igniterwarm‐up.
Westronglyrecommend
thattheinstallationis
carriedoutbyaqualified
gasapplianceengineer.
Takecaretofollowthe
recommendedfitting
instructionscarefully.
Failuretodosowillvoid
thewarrantyand
mayleadtopersonal
injuryordamageto
property.
FireHazard
Undernocircumstances
exceedthespecified
voltageof120volts.
Ensurethatcomponents
donotcomeintodirect
contactwithwater(for
example,spray,dripping
waterorrain).Improper
anddangerousoperation
canresultfromwiring
errors.Ensurethatwiring
isroutedsecurely,and
awayfromanyflame.
ShockHazard
Alwaysturnoff
electricpowerbefore
workingonany
appliance.Ensureproper
connectionoflinehot
wires.
ExplosionHazard
Shutoffmaingasto
appliancebefore
installationbegins,and
donotreconnectuntil
installationisco

Summary of content (2 pages)