Instructions / Assembly
HOTSURFACEIGNITERFITTINGINSTRUCTIONS
5.Duringigniterwarm‐up,usingatrueRMSvoltmeter,measurethe
voltageacrosstheigniter.Voltageshouldbebetween50VACand120
VAC.
6.MakesuretheGlo‐Stix™igniterdoesnotremainenergizedinthe
flameformorethanafewseconds.
7.Replacetheburnercompartmentdoor.
8.PlaceGlo‐Stix™upgradelabelonfrontoftheappliance,writethe
dateofinstallationandyourcontactdetails.