Specifications
Doc No. 006-0211-00 Rev C Page 29 of 63
Figure 23. Select Alarm Trip Delay Screen
When at least one threshold is reached for at least the Alarm Trip Delay time
programmed the alarm trips. When the alarm trips, the following events occur
automatically:
1. If the relay board is installed as an option, the relay contacts close.
2. A short 5 second alarm is sounded on the Scout-3000 (the volume is the same
as is set in the Display/Sound menu).
3. The event is recorded to the USB thumb drive in a file called “ALARMLOG.CSV”.
The file is appended with one line, in a comma-separated text format, showing
the information about the alarm. An example of one trip event in the file is:
"TripTime=Jan 27, 2011 Thu 09:35:00","Tool= 94351 MultiESP","Alarm=Motor
Temp > 250.0 °F","LastValue=253.0 °F"
4. All data values on the main Scout-3000 screens turn red and the bottom right
corner of the screen flashes “ALARM TRIPPED!” Pressing the “ALARM
TRIPPED!” text takes you directly to the Relay Alarm Setup menu screen.