Specifications

Doc No. 006-0211-00 Rev C Page 42 of 63
Figure 37. RFU in the Communications Options
4. Select USE SERIAL CONNECTION button.
5. Select 115200 from BAUD RATE DROPDOWN BOX.
6. Select correct com port from the COMM PORT DROPDOWN BOX.
7. Clear ENABLE PROCESSOR DETECTION CHECKBOX.
8. Check USE USB TO SERIAL CONVERTER CHECKBOX.
9. Click OK
10. Select FILE from the top toolbar.
11. Select LOAD FLASH IMAGE
12. Select file from wherever it has been stored. Standard is SCOUT-3000 RCM
Firmware xx.bin
13. Some GE installations use SCOUT-3000 RCM Firmware 20ggemodbus.bin for
use with the Vector 7 drive running the basic program.
SPS-1500
Updating SPS-1500 Firmware Using Hyper-Terminal Utility
Parts Required:
1. USB Cable, A-B (P/N 136-0076-01)
2. Computer with Hyper-Terminal software
3. Current released version of SPS-1500 firmware
4. Power supply for SPS-1500
Procedure:
1. Make sure the power to the SPS-1500 is off and unplug the RS-485 Modbus
interface.
2. Connect the USB Type A to B Cable (P/N 136-0076-01) to the port labeled “USB”
on the SPS-1500.