Table 2. Available Configurations
TYPE NUMBER TRANSMITTER
ELECTRICAL
POSITION
SWITCHES
TRAVEL
DUAL
POTENTIOMETER
Standard Stroke
Up to 105 mm
(1)
(Up to 4.125 Inches)
Long‐Stroke
Up to 610 mm
(1)
(Up to 24 Inches)
4210
4211
4212
4215
X
X
- - -
X
X
- - -
X
X
X
X
X
X
- - -
- - -
- - -
- - -
- - -
- - -
- - -
X
4220
4221
4222
X
X
- - -
X
- - -
X
- - -
- - -
- - -
X
X
X
- - -
- - -
- - -
1. See table 3 for zero and span limits.
Table 3. Zero and Span Limits
(1)
TYPE NUMBER
DEGREES OF
POTENTIOMETER ROTATION
CONNECTION
(2)
SLIDING‐STEM ACTUATOR TRAVEL
mm INCHES
Zero
Position
Span
Zero
Position
Span
Zero
Position
Span
Min. Max. Min. Max. Min. Max.
4210
4211
4212
4215
0 to 90 15 90
1 0 to 51 8 51 0 to 2 0.315 2
2 0 to 105 17 105 0 to 4.125 0.670 4.125
4220
4221
4222
0 to 884 150 884
12‐Inch Transducer 0 to 305 105 305 0 to 12 4.125 12
24‐Inch Transducer 0 to 610 305 610 0 to 24 12 24
1. Zero position is the range of values over which the transmitter zero can be adjusted. Span is the range of shaft rotation or stem travel the transmitter span can be adjusted. For example, a zero
position of 45 degrees and a span of 15 degrees means the transmitter output is 4 mA DC after 45 degrees of shaft rotation. The output then increases from 4 mA DC to 20 mA DC as the shaft ro
tates from 45 to 60 degrees.
2. Refer to figures 15, 22, and 23 for locations of connections.
Figure 3. Power Supply Requirements
10
11
1000
750
500
250
0
650
0
3020
MINIMUM TRANSMITTER TERMINAL VOLTAGE
NOMINAL SUPPLY VOLTAGE
MAXIMUM TRANSMITTER TERMINAL VOLTAGE
OPERATING
REGION
LOAD IMPEDANCE (OHMS)
POWER SUPPLY VOLTAGE (VOLTS DC)
24
A6765