Instruction manual

Instruction Manual
D200354X012
4200 Transmitters
July 2013
7
WARNING
Failure to follow these conditions of “safe use” could result in personal injury or property damage from fire or explosion, or
area re‐classification.
CSA
Intrinsically Safe, Explosion-proof, Dust Ignition-proof
No special conditions for safe use.
Refer to table 5 for approval information, figure 24 for CSA loop schematics, and figure 26 for typical CSA/FM approval
nameplates.
Table 5. Hazardous Area Classifications—CSA (Canada)
Certification
Body
Type Certification Obtained Entity Rating Temperature Code Enclosure Rating
CSA
4211, 4221
Intrinsically Safe
Class I,II,III Division 1 GP A,B,C,D,E,F,G
per drawing GE16020
Ui = 30 VDC
Ii = 150 mA
Pi = 1.0 W
Ci = 5 nF
Li = 0 mH
T4 (Tamb 71°C) 4X
4210, 4211,
4212, 4215,
4220, 4221,
4222
Explosion‐proof
Ex d IIC T5
Class I, Division 1 GP B,C,D T5
- - - T5 (Tamb 71°C) 4X
4210, 4211,
4212, 4215,
4220, 4221,
4222
Class II Division 1 GP E,F,G T5 - - - T5 (Tamb 71°C) 4X
FM
Intrinsically Safe, Explosion-proof, Dust Ignition-proof, Non‐Incendive
No special conditions for safe use.
Refer to table 6 for approval information, figure 25 for the FM loop schematic, and figure 26 for typical CSA/FM
approval nameplates.
Table 6. Hazardous Area Classifications—FM (United States)
Certification
Body
Type Certification Obtained Entity Rating Temperature Code Enclosure Rating
FM
4211, 4221
Intrinsically Safe
Class I,II,III Division 1 GP A,B,C,D,E,F,G
per drawing GE16019
Vmax = 30 VDC
Imax = 150 mA
Pi = 1.0 W
Ci = 18 nF
Li = 0 mH
T4 (Tamb 71°C) 4X
4210, 4211,
4212, 4215,
4220, 4221,
4222
Explosion-proof
Class I Zone 1 AEx d IIC T5
Class I, Division 1 GP A,B,C,D T5
- - - T5 (Tamb 71°C) 4X
4211, 4221
Class I Division 2 GP A,B,C,D T4
Class II Division 2 GP F,G T4
- - - T4 (Tamb 71°C) 4X
4210, 4211,
4212, 4215,
4220, 4221,
4222
Class II Division 1 GP E,F,G T5 - - - T5 (Tamb 71°C) 4X