LIGHT FLASH JUMPER:
This jumper is used to determine the light flash output. In the (+) position, the on-board
relay is enabled and the unit will output (+)12V on the WHITE wire, H1/2. In the (-) position, the on-board relay is
disabled. The WHITE wire, H1/2, will supply a 200 mA (-) output suitable for driving factory parking light relays.
There are times when you need to temporarily bypass all sensor inputs to the unit, such as when remote starting
the vehicle. Anytime an auxiliary channel output is used, all inputs are bypassed for 5 seconds. During the 5 second
bypass period, ground can be supplied to the H1/6 Blue wire without triggering the unit. When the 5 second bypass
period ends, if the unit sees ground on the H1/6 Blue wire, all trigger inputs except the door trigger input will remain
bypassed until 5 seconds after ground is removed from the BLUE wire. This can be done using the status output
of a 551T remote start unit as shown below:
BYPASSING SENSOR INPUTS
INTERNAL PROGRAMMING JUMPER