Owner`s manual

11
nuisance prevention circuitry
®
Your system has Nuisance Prevention Circuitry
®
(NPC
®
) to prevent
annoying repetitive trigger sequences caused by faulty door pin switch-
es or environmental conditions such as thunder, jackhammers, airport
noise, etc.
Here’s how NPC
®
works: If the alarm is triggered by the same sensor or
switch three times within a 60-minute period, your system interprets
this pattern of triggers as false alarms. After the third trigger, your sys-
tem ignores, or bypasses, that sensor or switch (along with any other
sensors or switches sharing the same zone) for 60 minutes. If the
bypassed sensor is triggered again while it is already being bypassed,
the 60-minute bypass period will start over. This ensures that a sensor
that is continually being triggered will remain bypassed.
note: Arming and disarming the system does not reset the
Nuisance Prevention Circuitry
®
. The only ways to reset a
bypassed zone are for that zone not to be triggered for 60
minutes or to turn the ignition key on. When testing your sys-
tem, it is important to remember that this circuitry can cause
zones to be bypassed and appear to not work. If five chirps
are heard when disarming the system, the NPC
®
was
engaged. To clear the memory, turn the ignition key on.