Operating instructions

Doc.No.: 99100-003-CA
Page 3 of 4
LED indicators
Led status conditions:
Dark / no light
7
Slow flashing
=
Fast flashing
Steady light
Green
LED
Red
LED
Status
Power off – no operation
7
Idle – status OK
7 7
Idle – blinking generator OK – opposite generator power failure
The remaining generator is still working, but the module requires service
= =
Idle – generator OK – main power supply failure / below 15-18V
The generator is still functional – the power source must be checked
The alarm module is generating an alarm tone, section OK
=
The alarm module is generating an alarm tone, but the output level from the
displaying section is below the acceptable limit. Thus, the alarm section has gone to
idle and the other section has taken care of the functionality.
The generator may still work if the other section is displaying OK. Else not.
Service is required.
The alarm module is trying to generate an alarm tone. The remaining section, after
primary section fail, is outputting a signal level below the acceptable limit, but is still
trying to output.
The generator is not working and immediate service is required.
Idle – the generator module is faulty.
Service is required
Handbook page
51/94