Operating instructions

Doc.No.: 99100-003-CA
Page 4 of 4
SOFTWARE:
Phontech will always configure the Alarm generator according to the requirement. Due to the full
flexibility of the functionality it is possible to generate custom designed functionality as well as
standard.
Within each software version there might be DIP-switch parameter settings available. The following
list describes the standard software facilities.
Prog:
Ver.
Description:
1.0
1.1
1.2
1.3
STANDARD ALARM FOR SPA 1500:
1. Priority alarm = GENERAL ALARM – 7 short bursts (1 sec. ON / 1 sec. OFF)
followed by 1 long burst (7 sec.). Tone - 1 kHz
2. Priority alarm = FIRE ALARM (ref. DIP SW. Table below:
DIP SW:
1
1 2 3 4 5 6 7 8
Facility
0 x x x x x x x Continuous tone 800Hz
1 x x x x x x x Bell ring tone (1 sec ON / 1 sec. OFF)
1.3
x # # x x x x x Ding-Dong tone volume setting relative to alarm / overall volume
adjustment:
DIP SW 2 DIP SW 3 Volume level
1 1 0 dB
0 1 -6 dB (factory default)
1 0 -12 dB
0 0 -18 dB
1
DIP Switch setting: 0=OFF / 1=ON / x = Don’t care / # = see details
Handbook page
52/94