Installation guide

52 © 2003 Directed Electronics, Inc. Vista, CA
To enter or exit timer mode manually:
1. Make sure the remote start system is not operating the engine.
2. Turn the ignition on.
Timer Mode will be exited and the parking lights will flash four times.
table of zones
When using the Diagnostic functions, use the Table of Zones to see which input has triggered the system. It is
also helpful in deciding which input to use when connecting optional sensors and switches.
NOTE: The Warn Away® response does not report on the LED.
shutdown diagnostics
1. With the ignition OFF, press and HOLD the Valet/Program button.
2. Turn the ignition ON and then back OFF while HOLDING the Valet/Program button.
3. Release the Valet/Program button.
4. Press and release the Valet/Program button. The LED will report the last shutdown for one minute or until
the ignition is turned on.
to perform shutdown diagnostics
ZONE NO. TRIGGER TYPE INPUT DESCRIPTION
1 Multiplexed Input BLUE (H1/6)
2 Multiplexed Shock Sensor Input Mux BLUE wire.
3 Door Trigger GREEN (H1/5) and VIOLET (H1/7).
4 Multiplexed Shock Sensor Mux GREEN wire
5 Ignition Yellow ribbon harness wire
6 Hood Brake Trigger GRAY on the 6-pin shutdown harness.