Specifications
TM 11-5820-670-30
2-26. TROUBLESHOOTING CHARTS.
(CONT)
CONNECT EQUIPMENT AS
SHOWN IN TRANSMITTER
POWER OUTPUT PERFOR-
MANCE TEST (PARA 2-11).
CHART 2-13
Transmitter Power Output (HI) Troubleshooting
(Sheet 1 of 3)
NOTES
Frequency should be within ± 350 KHz of the
control unit setting from 30.00 to 52.95 MHz
and within ± 450 KHz for frequencies at 53.00
to 75.95 MHz.
EL1AT208
REPLACE MODULE A6300
ON A6000 ASSEMBLY
(PARA 2-48).
PERFORM TRANSMITTER
POWER OUTPUT PERFOR-
MANCE TEST (PARA 2-11).
2-91