2-34. NARROW BAND DEVIATION ADJUSTMENT.
(CONT)
INITIAL EQUIPMENT CONTROL SETTINGS
Set equipment controls as indicated in the following table.
CONTROL AND SWITCH SETTINGS
EQUIPMENT
CONTROL OR SWITCH
TS-2575/ARC-131
MODE SWITCH
VOL
SQUELCH switch
FREQ sel
WIDE BAND-NAR BAND
TRANSMIT switch
AN/URM-127
OUTPUT FREQUENCY
AMPLITUDE CONTROL
T/R
fully clockwise
DIS
60.05 MHz
WIDE BAND
OFF
1000 Hz
0.39 volt as observed on
ME-30E/U
ADJUSTMENT PROCEDURE
1. Set TS-2575/ARC-131 TRANSMIT switch to ON.
POSITION/SETTING
2. Adjust potentiometer R8605, on module A8600, to provide 8 kHz deviation as indicated on
deviation meter.
EL1AT242
2-141