2-37. HOMING ADJUSTMENT.
(CONT)
EL1AT249
4.
5.
6.
7.
8.
Adjust vertical needle adjust potentiometer R4805, located on homer-detector amplifier
assembly for a center-scale indication on homing indicator.
Vary signal generator output from minimum signal to 10 microvolt. Flags on homing indicator
should disappear when signal generator output is 1.2 microvolt or less; vertical needle
should stay centered ( ± 1/8 inch).
Set signal generator output to 35 microvolt and adjust horizontal needle potentiometer R4830,
located on homer-detector amplifier assembly, so homing indicator horizontal needle is
1/8 inch below center of indicator.
Adjust signal generator output for 10 microvolt. Set test set LEFT HOMER ATTEN to 3 db, and
adjust center course sensitivity potentiometer R4826 so homing indicator vertical needle
deflects right of center one-half of full scale.
Set RIGHT HOMER ATTEN to 3 db and LEFT HOMER ATTEN to 0 db. Repeat step 7 and ensure
homing indicator vertical needle deflects left of center one-half of full scale.