11.ELECTRONICCONTROL
11.1KEYCOMBINATIONS
11.1.1BASICOPERATION/CUSTOMERSETTINGS
Seealsopage10"Firstrun/CustomerMenu"andpage32"CounterFunctions".
X=buttontobepushed
BASICOPERATION STOP PROGR. SERVICE ON/OFF REQUIREMENTS HOOD
MachineON X Machine"off" OpenorClose
MachineOFF X Machine"off"atanytime OpenorClose
Drainprogram X>3s Startatanytime Close
ProgramselectionX Machineon/Fillprogramcompleted OpenorClose
Programstart X Machineon/Fillprogramcompleted Close
TemperaturedisplayX>3s Temperaturedisplayfor10seconds
OpenorClose
SpecialprogramsXMachineon/Fillprogramcompleted
OpenorClose
CUSTOMERSETTINGS
X X MACHINEOFF OPEN
DISPLAY
UPPER LOWER
Detergentdosage CH1 valueC16
Selectfunctionwiththeprogrambutton.
SetvaluewiththeON/OFFbutton.
Open
Rinseaiddosage CH2 valueC18
Open
DetergentdosageCold1 CH3 valueC19
Open
DetergentdosageCold2 CH4 valueC20
Open
Hardness H01‐H04
Open
Washcyclecounter P+C74 valueC73
ResetonlybyService.
Open
Watercounter‐Total E+C78 valueC7
Open
Watercounter‐Demi d+C80 valueC79Resetbypus hingtheON/OFFbuttonfor3seconds.
Open
CLOSEHOOD
Hoseprimingdetergent
SF1 0‐1
Selectfunctionwiththeprogrambutton.
ActivateappropriatedosingpumpwiththeON/OFFbut ton.
Close
Hoseprimingrinseaid
SF2 0‐1
Close
Acousticsignal
S 0‐1 Activate/deactivatewiththeON/OFFbutton.
Close
Chemicalssensor
CH 0‐1 Activate/deactivatewiththeON/OFFbutton.
Close