Service manual

. R&D, HOBART CHINA AMX/AM900 / 27
11.1.2SERVICEMENU
Requirements:MachineOFFandHoodopen.
PushStop,ProgramandServicebuttontoentertheServiceMenu.
EXITthetestprogrambyopeningthehood(onlypossiblewithmenuitem"outputstest").
DISPLAY: UPPER LOWER
 S01
‐‐0 (ON/OFFbuttonilluminates)
CLOSEHOOD(doorswitchtestS1) S02
‐‐1
SelectappropriateInputorOutputbypushingtheProgrambutton.
Inputstest: 
X13.3 Impellerswitch S02
‐‐0
nosignal/‐‐1signalfromS2
PushON/OFFtoactivateadditionallyfillvalveY1.
‐‐0
/‐‐1willbedisplayedalternately
X13.5 Saltswitchstatus S03
‐‐0 saltcontainerisfilled/‐‐1when
X13.7 Strainer S04
‐‐0
notinplace/‐‐1strainerinpla
X13.9 Reserve S05
‐‐0
X13.11 Reserve S06
‐‐0
X12.3 Detergentdeficiency1) S07
‐‐0
nodeficiency/‐‐1whenempty
X12.4 Rinseaiddeficiency1) S08
‐‐0
nodeficiency/‐‐1whenempty
1) Push ON/OFF to activate the respective dispenser
... movinglightpointdispenser
Activationwillpersistuntilremedyofdeficiency.
Temperatureprobestest: 0105°C=okay/‐‐1=shortcircuit(>99°C)/‐‐2=opencircuit(<0°C)
X14.1/2
Temperaturesensor
B1 F01
actualTemperature
X14.3/4 TemperaturesensortankB2 F02
actualTemperature
Pressuretransmittertest: 0.3‐4.0V=okay/‐‐1=>4.0V/‐‐2=opencircuit<0.3V
X14.7
Pressuretransmitter
B3 F03
voltagedisplay(boosterlevel)
X14.10 Pressuretransmittertank B4 F04
voltagedisplay(tanklevel)
Outputs ‐0=notactive/‐‐1=active
Hoodmustbeclosed. SelectedoutputcanbeactivatedwiththeON/OFFbutton.StartingfromA01:pushStopbuttontoscrollback.
VoltagesupplyTri ac RL1.1 A00 ‐‐0
X1.1/3 BypassTriacRL1 A01‐0
X2.1/2 Tankheating E2(K2) RL2 A02 ‐‐0
X3.1/3 WashpumpHigh RL3 A03‐0 AUXX/AUP
 WashpumpLow  0 AMXT/AUXT
X4.1/3 Externalfill Y2 RL4 A04 ‐‐0 (option)
X5.1/3 Detergentdosage M4 RL5 A05‐0
X6.1/3 Rinseaiddosage M3 RL6 A06 ‐‐0
X7.1/3 Fillvalve Y1 RL7+RL14 A07‐0
X8.1/3 Drainpump M5 RL8 A08 ‐‐0
X9.1/3 Rinsepump M2 RL9 A09‐0
X10.1/3 Boosterheating E1 RL10 A10 ‐‐0
X21.6 Softener‐saltingA Y3.1 RL11 A11‐0 onlywithbuilt
X21.7 Softener‐saltingB Y3.2 RL12 A12 ‐‐0 onlywithbuilt
X21.8 FillBA Y4.1 RL13 A13‐0 onlywithbuilt
X21.9 Drain/booster Y4.2 RL14 A14 ‐‐0 onlywithbuilt
X22.1/3 ReserveRL15 A15‐0 onlywithbuilt
X23.1/3 Reserve RL16 A16 ‐‐0 onlywithbuilt
X24.1/2 PFK1RL17 A17‐0 onlywithbuilt
X25.1/2 PFK2 RL18 A18 ‐‐0 onlywithbuilt
X26.1/2 PFK3/RL19 A19‐0 onlywithbuilt
 WashpumpHigh  AUXXT
X1.1/3 Washpump RL1+RL1.1 A20 AMX/AMXX/AUXX/AUP
WashpumpLow AMXT/AUXXT
 Handlelightning Grl‐FF
Operationunittest BAE ‐‐0
 Counterreset(C72C80  rES‐0 /‐‐1whenON/OFFbuttonis