11.1.3PROGRAMMING/MODIFICATIONOFBASICDATA/SOFTENERTEST
Requirement:machine"OFF"andhoodopen.
–PushProgramandServicebuttontogether.
Softwarereleasewillbedisplayedshort‐time.
–PushStopbuttontoselectthemenuitem.
U01=Machinetypeselection
U02=Basicdatasheet
U03=Softenertestprogram
–Theselectedfunctionwill
beconfirmedwiththeON/OFFbuttonandindicatedbytheilluminatedON/OFFbutton.
Red=Machinetypeselection
Blue=Basicdatasheet
Green=Softenertestprogram
MACHINETYPESETTING:U01
–SetmachinetypewiththeStopbutton(01–20,sequentialscanonly).
ProgramNumberseepage4.
–PushON/OFFbuttonfor2seconds.
Theselectedprogramwiththebasicdata’swillbesavedandthe"Red"illuminated
ON/OFFbuttonswitchesoff.
MODIFICATIONOFBASICDATA:U02
–SetfunctionwiththeStopbutton(forwards)orfirstProgrambuttonandthenStopbutton(backwards).
(Sequentialscanorquickscanbyholdingthebutton.)
–Changevalueupwards(+)withtheProgrambuttonanddownwards(–)withtheServicebutton.
(Sequentialscanorquickscanbyholdingthe
button.)
–Decimalpointswillappear.
–PushandholdtheON/OFFbutton.
Newvalueissavedwhenthepointsdisappear.
SOFTENERTESTPROGRAM:U03
–PushON/OFFbutton.
Testprogramstartsaccordingtodiagram(seepage21).