Service manual

AMX/AM900 SERVICE MANUAL
30/AMX/AM900 . R&D, HOBART CHINA
11.2.2EXTENSIONBOARDA3

NOTE:
Theadditionalboard(8975461)isonlybuiltinatmachineswithsoftener.
ThisPCBhasthreepotentialfreecontacts.Eachonecanbeassignedtodifferentswitchingfunctionsviaone
parameter(onlyonextensionboard):
Parameter [S61] = RL17(X24)switches: PFK1
0 = machine"On"
1 =
program"On"
2 =
temperatureF02/F05belowpresetvalue
3 =
fillorwashprogramactive
Parameter [S62] = RL18(X24)switches: PFK2
0 = program"On"
1 =
machine"On"
2 =
rinsepump"On"(switchoffdelay[C86])
3 =
fillprogramactive
Parameter [S61] = RL17(X24)switches: PFK3
0 = fillprogramactive
1 =
rinsepump"On"(switchoffdelay[C86])
2 =
temperatureF02/F05belowpresetvalue
3 =
fillorwashprogramactive