12.FAULTS
12.1UNCRITICALFAULTS
Fill,washanddrainprogramcanbestarted.
Duringthefillprogram,uncriticalfaultsareonlyindicatedbytheindicatorlightsanderrorcodes(none
green/redflashingON/OFFbutton).
INDICATOR TheON/OFFbuttonisflashingGREEN/REDalternately.
Rinse Wash Lamp FAULT PROGRAM
AL
Drainfault
Levelswitchvalue[F11]stillexceededattheendofthe drain cycle.
Toreset,repeatdrainprogramuntilvalueisbelow[F11].
F11
Possiblecause
1. Kinkeddrainhose.
2. Drainpumpdoesnotrun(jammedor
defective).
3. PressuretransmitterB4defective
(wiring,PCB).
4.Trappossiblyclogged.
Remedy
1. Placedrainhosecorrectly.
2. Checkdrainpump,dismantleifnecessary.
3. Checkvoltagelevel(servicemenu).
4. Checktrap.
HEI
Thermostop Thethermostoptime[C25]isexceeded(max.heatingperiodforwashandfill
cycle).
Resetviamachine"OF‐ON".
C25
S02
S58
Possiblecause
1. Boosterheatingdefective.
2. Missingphases.
3. Machinesingle‐phaseconnected(230V).
4. Tankheatingdefective(withtermostoptank)
parameterS58
Remedy
1. Replaceboosterheating.
2. Checkphases(alsoatsite).
3. Connecttothree‐phasecurrentifpossible.
4. Replacetankheating
CH1
CH2
Chemical
deficiency
DetergentdeficiencyX12.3"on"/rinseaiddeficiencyX12.4"on".
Ifbothcontainersareempty,CH1/CH2isdisplayedalternately.
S06
Possiblecause
1. Chemical container empty / suction hoses not
filled.
2. Adjustment of chemical deficiency sensors not
correct.
3. Missingelectricalsupply(X12.1/2).
Remedy
1. Refillcontainer/carryouthosepriming.
2. Checksettings(seechap.7.3.2,page 17).
3. Checkvoltage(X12.1+5V,X12.20V)/check
crimpconnection.
SAL
Saltdeficiency Softenersaltdeficiencyindication–X13.5"on"
(onlyifsoftener[S05]="1").
S05
Possiblecause
1. Saltcontainerempty.
2. Floatswitchinsidesaltcontainerjammed[S3].
3. LoosecontactonPCB(X13.5/6).
Remedy
1. Refillcontainerwithregenerationsalt.
2. Loosethecontaineralittleandshakeslightly.
3. Checkcrimpconnectionandcontacts.
d0
Externalwater
treatment(option)
Onlyifactivatedinservicemode[S18].
Thepresetwaterquantity[C79]+[C80]isreached(down‐counter).
Forresetseecustomermenu.
S05
Possiblecause
1. Counter reading of preset water quantity
(liter)is"0".
2. Switching function [S18] is set to "1" without
specifiedwaterquantity
Remedy
1. Resetcounter(seecustomermenu).
2. Enterthedesiredwaterquantity(liter).
CLOSEHood
Cause
Fillcycleinterruptedashoodisopen.
Remedy
Closehood,fillingwillcontinue.
(runningindication)