Service manual
. R&D, HOBART CHINA AMX/AM900 / 33
12.2CRITICALFAULTS
Onlythedrainprogramcanbestarted.Fillprogramandallwashprogramsarelocked.
INDICATOR TheON/OFFbuttonilluminatesRED.
Rinse Wash lamp FAULT PROGRAM.
F01
‐‐1
‐‐2
Temperatureprobe
BOOSTERB1
BoosterheatingRL10willbeswitchedoffimmediately.
Fillandwashprogramsarelocked,drainprogramcanbestarted.
Possiblecause
1. ‐‐ 1= shortcircuit (temperature probeorwires
toprobe).
2. ‐‐2=opencircuit.
3. Inlettemperaturetolow.
Remedy
1. Checkwires,replacetemperatureprobe.
2. Replace wiring, replace temperature probe i
f
necessary.
3. Checkinlettemperature.
F02
‐‐1
‐‐2
Temperatureprobe
TankB2
TankheatingRL2willbeswitchedoffimmediately.
Fillandwashprogramsarelocked,drainprogramcanbestarted.
Possiblecause
1. ‐‐1=shortcircuit(temperatureprobeorwires
toprobe).
2. ‐‐2=opencircuit
Remedy
1. Checkwires,replacetemperatureprobe.
2. Replacewiring, replacetemperatureprobe if
necessary.
F03
‐‐1
‐‐2
Pressuretransmitter
BOOSTERB3
ControlofinputvoltageX14.7–min.0.3Vuptomax.4.0V.
Iftheinputvoltageisoutofrange,therunningprogramwillbestopped.
Fillandwashprogramsarelocked,drainprogramcanbestarted.
Possiblecause
1. ‐ ‐ 1 = short circuit (transmitter or wires to
transmitter)/>4.0V.
2. ‐‐2=opencircuit/<0.3V.
Remedy
1. Checkwires,replacetransmitterB3.
2. Replacewiring,replaceB3ifnecessary
F04
‐‐1
‐‐2
Pressuretransmitter
TankB4
ControlofinputvoltageX14.10–min.0.3Vuptomax.4.0V.
Iftheinputvoltageisoutofrange,therunningprogramwillbestopped.
Fillandwashprogramsarelocked,drainprogramcanbestarted.
Possiblecause
1. ‐ ‐ 1 = short circuit (transmitter or wires to
transmitter)/>4.0V.
2. ‐‐2=opencircuit/<0.3V.
Remedy
1. Checkwires,replacetransmitterB4.
2. Replacewiring,replaceB4ifnecessary.
‐‐3
Pressuretransmitter
TankB4
Softener
Themax.waterquantity[C82]isexceededandvalue[F16]isnotreached.Only
"draining"possible.
C82
F16
Possiblecause
1. Airtrapblockedorleaky.
2. Hosetopressuretransmitterleaky.
3. Valve Y 4.2 locked (drain direction) or coil
defective.
4. Extension board not correctly plugged to Main
PCB.
Remedy
1. Checkairtrap,cleanorreplaceifnecessary.
2. Replacehose.
3. Run Softener Test.
Replace switching valve if
necessary.
4. Plugincorrectly.
Toquitthefault:startdrainprogramorreloadmachineprogramNo.(U01seepage23).
SIE
STRAINER
CONTROL
Reed‐switch[S4](X13.7)morethan5seconds"off".
Startoffillandwashprogramislockedautomatically.
S38
Possiblecause
1. Tank strainer is missing or not correctly
positioned.
2. Magnetatthestrainerismissing.
3. Reedswitchinwrongposition.
4. Cablebreak.
Remedy
1. Putstrainercorrectlyinplace.
2. Fitmagnet.
3. Putreedswitchincorrectposition.
4. Replacereedswitchandcable.