Service manual

AMX/AM900 SERVICE MANUAL
34/AMX/AM900 . R&D, HOBART CHINA
INDICATOR TheON/OFFbuttonilluminatesRED.
Rinse WashLamp FAULT PROGRAM
FIL
FILL1
ThefillvalveY1(RL7)istriggeredandtheimpellerswitchS2doesnotcount(no
impulsesonX14.3).
ResetviainputpulsesonX14.3ormachine"OF".
Possiblecausewithincomingwater
1. Bad contacts at impeller switch plug (airgap) or
PCB.
2. ImpellerswitchPCBnotcorrectlylocked.
3. Reedswitchinwrongposition.
Possiblecausewithoutincomingwater
1. Shutoffvalveisclosed.
2. FillvalveY1defective(wiringandpin).
3. No
outputsignalfromPCBA1(X7.1/3).
Remedy
1. Checkcontacts,solderplug(airgap)ifnecessary.
2. CheckPCBandlockinplace.
3. Putreedswitchincorrectposition.
Remedy
1. Openshutoffvalveatsite.
2. Check fill valve via service mode and replace i
f
necessary.
3. ReplacePCB.
FIL
FILL2
Exceededfilltime[C43].
ThefillvalveY1(RL7)andallotheroutputswillbeswitchedoffimmediately.
Resetviamachine"OF".
Possiblecause
1. Seeabove.
2. Lineflowpressureverylow.
3. Linestrainerclogged.
Remedy
1. Seeabove.
2. Checklineflowpressure.
3. Cleanlinestrainer.
FIL
FILL3
Externalfillvalveistriggered,tankleveldoesnotrise.
Possiblecause
1. Shutoffvalveisclosed.
2. FillvalveY1defective(wiringandpin).
3. Linestrainerclogged.
Remedy
1. Openshutoffvalveatsite.
2. Checkfillvalveviaservicemodeandreplaceif
necessary.
3. Cleanlinestrainer
UL
OVERFLOW
PROTECTION
Requirement:machine"off"or"on"/hood"open"or"closed"S1.
When[F18]isexceeded,arunningprogramwillbestopped:
‐after5seconds[S37]="1"
‐immediately[S37]="0".
ThedrainpumpRL8willbeswitchedonuntil[F17]is
belowpresetvalue.
Possiblecause
1. Fill valve is jammed and water is running
permanently.
2. Hosefromairtraptopressuretransmittertank
(B4)isleaky.
3. Notenoughwaterispumpedout.
‐Drainpumpclogged.
‐Kinkeddrainhose.
Remedy
1. ReplacefillvalveY1
2. Draintankmanuallyandreplacehose.
3. Draintankmanually.
‐Dismantleandcleandrainpumporreplaceif
necessary.
‐Placedrainhosecorrectly.
ERR
INTERFACE
Communicationproblem.
Possiblecause
1. Brokenconnection:Display/MainPCB
2. DefectiveCircuitBoard.
Remedy
1. Checkplugs/cableandconnectcorrectly.
2. ReplacePCB.
12.3OTHERINDICATIONS
INDICATOR TheON/OFFbuttonisflashingblue/REDalternately.
Rinse Wash Lamp FAULT PROGRAM
NegativePressure

Possiblecause
1. Washtankfiltersblocked.
Remedy
1. Removeandflushstrainers.