9.6 Analogue inputs (Control panel: Menu PAR -> P6)
6.3 AI1 CUSTOM MAXIMUM
6.4 AI1 FILTER TIME
6.6 AI2 CUSTOM MINIMUM
6.7 AI2 CUSTOM MAXIMUM
These parameters set the analogue input signal for any input signal span from
minimum to maximum.
6.8 AI2 FILTER TIME
This parameter, given a value greater than 0, activates the function that filters
out disturbances from the incoming analogue signal.
Long filtering time makes the regulation response slower. See
%
100%
63%
Par. 6.4
Par. 6.8
t[s]
Filtered signal
Unfiltered signal
Figure 9.15.