User manual
82 • vacon parameters
Tel. +358 (0)201 2121 • Fax +358 (0)201 212205
8
8.9 Digital outputs (Control panel: Menu PAR -> P8)
P7.5
Encoder direc-
tion
0 2 0 1233
0 = Disable
1 = Enable / Normal
2 = Enable / Inverted
P7.6
Encoder pulses /
revolution
1 65535 ppr 256 629
Pulse count of encoder
per round. Used for scal-
ing encoder rpm monitor
value only.
Config DI5 and
DI6
0
2 0 1165
0 = DI5 and DI6 are for
normal digital input
1 = DI6 is for pulse train
2 = DI5 and DI6 are for
encoder frequence mode
Code Parameter Min Max Unit Default ID Selections
P8.1
RO1 signal
selection
0Varies 2 313
0 = Not used
1 = Ready
2 = Run
3 = Fault
4 = Fault Inverted
5 = Warning
6 = Reversed
7 = At Speed
8 = Motor regulator active
9 = FB Control Word.B13
10 = FB Control Word.B14
11 = FB Control Word.B15
12 = Output freq superv.
13 = Output torque superv.
14 = Unit temperature superv.
15 = Analogue input superv.
16 = Preset Speed Active
17 = External Brake ctrl
18 = Keypad control active
19 = I / O control active
20 = Temperature supervision
P8.2
RO2 signal
selcetion
0 Varies 3 314 As parameter 8.1
P8.3
DO1 signal
selcetion
0 Varies 1 312 As parameter 8.1
Table 8.9: Digital outputs
Code Parameter Min Max Unit Default ID Note
Table 8.8: Pulse train/Encoder
i
i
P7.7
i
i