Specifications

JNS Engineering 19 3/18/2013
Programming options using BitWriter
Most of the factory default values can be used without changes. The optional
BitWriter device makes programming very simple. The following changes to the
defaults are recommended. This first list contains values that COULD be
programmed manually using the valet button method:
Menu Item
Feature
Option
1
Transmission Mode
Automatic (opt 2)
2
Engine Checking Mode
Tachometer (opt 4)
5
Activation Pulse Count
2 (opt 2)
6
Turbo Mode
On 1 minute (opt 2)
11
Status 2 output
Pulse Rear Defogger (opt 3)
Table 6 – Menu 3 Remote Start Parameters
Transmission mode is set to automatic instead of manual to make it easier to
remote start the car. With the remote start wiring and neutral safety switch
installed it is unnecessary to use the manual configuration. The activation pulse
count is the number of “Timer” button presses needed to remote start the car.
Two is recommended to prevent accidental remote start. Turbo mode is an
optional turbo timer feature that can be activated using the button you wired into
H2-21. Status 2 output allows you to operate the rear window defogger while in
remote start mode. Program it if you have wired it up with H2-3.
The Aux timed outputs can be setup manually however timer values will default
to 30 seconds and can ONLY be programmed using BitWriter. It is not possible
to program an Icon Type for Aux 4.
Menu Item
Feature
Option
4
Aux 1 Timed Output
1 to 90 seconds (10 sec)
5
Aux 1 Icon Type
Trunk (opt 2)
6
Aux 2 Timed Output
1 to 90 seconds (10 sec)
7
Aux 2 Icon Type
Trunk (opt 2)
8
Aux 3 Timed Output
1 to 90 seconds (40 sec)
9
Aux 3 Icon Type
Sunroof (opt 2)
10
Aux 4 Timed Output
1 to 90 seconds (32 sec)
Table 7 – BitWriter Only Options