Installation guide
© 2004 directed electronics, inc.
39
to properly adjust this state-of-the-art sensor will give your customer years of unsur-
passed security and stop any returns for further adjustments.
1. Disarm system
2. Transmit Channel 16. (Press 3 times then 1 time)
z
The LED will turn on and the siren will chirp 1 time.
z
Primary (full trigger) zone adjustment has now been entered.
z
Primary zone can now be adjusted.
3. Adjusting Primary Zone
z
Press of the remote control to increase sensitivity.
z
Press of the remote control to decrease sensitivity.
z
The sensor Primary zone can be tested at any time during adjustment and
will generate 1 siren chirp each time the zone is activated.
4. Press to adjust Warn-Away zone
z
Siren chirps 1 time.
z
Warn-away Zone adjustment has now been entered.
z
Warn-away Zone can now be adjusted.
5. Adjust Warn-away Zone
z
Press to increase sensitivity.
z
Press to decrease sensitivity.
z
The sensor Warn-away zone can be tested at any time during adjustment
and will generate 1 siren chirp each time the zone is activated.
6. Press of the remote control to return to Primary zone adjustment and lock
in Warn Away zone setting.
z
Siren chirps 2 times
z
Primary zone can now be re-adjusted as described in step 3.
z
Or press again to lock in primary zone setting and exit
programming mode.
z
The siren will chirp 3 times when sensor adjustment mode has been exited.
z
AAuuttoo--ssccrroollll ffoorr aaddjjuussttiinngg sseennssiittiivviittyy
- press and hold or to
increase or decrease sensitivity setting several levels rapidly.