User`s manual
PTU-D300 User’s Manual (v2.18.0) Appendix A.: SPECIFICATIONS
page 34
A.4 D300 Payload Wiring PL01
10/23/2006
B CHA 232 TX A CHA 232 RX M 232 SGND
C CHB 232 RX P GENERAL N GENERAL L CHA TTL TX
PASSTHRU #2 PASSTHRU #3
D CHB 232 TX R PAYLOAD GND V GENERAL U VIDEO-2 GND K CHA TTL RX
PASSTHRU #1
E CHB 232 OTR S PAYLOAD DC T VIDEO-2 J TTL OP2
0-50VDC
F SHIELD G VIDEO-1 GND H VIDEO-1
BLACK designates D300 controller signals
RED (bold) denotes pass-thru from D300 input connector
· {R, S} are rated 3A
· {F, G, H, N, P, T, U, V} are rated 1A
CAUTION:
DO NOT EXCEED MAXIMUM RATED PASS-THRU AMPERAGES. FUSE PAYLOADS AT RATED TRIP VALUES.
D300 Payload PL01 Pinout (rev 1.3)