Installer-Programmable Features
To access the installer-programmable features, use the procedure defined in the User-Programmable s ection, but in step 4, hold and
press the side of the PlainView 2 Switch for 15 seconds. You will hear three confirmation chirps indicating that the system is in
installer-program mode.
Table of Installer-Programmable Features (1 chirp = OFF, 2 chirps = ON)
Fea ture
Select
Unmarked 1 Unmarked 2 Unmarked 3
1
Single/Double Lock Pulse
(1 chirp/2 chirps)
Accessory Output Timer
Duration
(10 seconds )
See NOTE 1
Door Ajar Warning /Delayed
Courtesy Lights
(1 chirp/2 chirps)
2
Single /Double Unlock Pulse
(1 chirp/2 chirps)
Auxiliary A Type
(Pulsed /Timed/Latched)
(1 chirp /2 chirps/3 chirps)
Auxiliary A (trunk release)
Interlock
(On/Off)
3
Lock/Unlock Pulse
3 second/1 second
(1 chirp/2 chirps)
Auxiliary BType
(Pulsed /Timed/Latched)
(1 chirp /2 chirps/3 chirps)
Auxiliary B Interlock
(On/Off)
4
Program Door Polarity
(Positive/Negative)
(1 chirp/2 chirps)
Auxiliary CType
(Pulsed /Timed/Latched)
(1 chirp /2 chirps/3 chirps)
Auxiliary C Interlock
(On/Off)
5
Program RPM
See Mandatory RPM
Programming section in this
binder
Diesel Engine/Gas Engine
(1 chirp/2 chirps)
(For IntelliStart 4 only)
AutoActivate Auxiliary C upon
Remote Arming
(On/Off)
6
Aux il iary Si ren Out put
(Constant/Pulsed)
(1 chirp/2 chirps)
NOT USED
Learn PageMate 4 ID or
Program SmartWindows 4
(Requires Optional
SmartWindows 4)
n
NOTE 1: Once this feature is selected, one chirp is provided to indicate that the timer has started. You can set this anywhere
from one second to four minutes. When the desired duration has been reached, press the unmarked side of the PlainView 2
switch. The system responds with two chirps to confirm the new system timer duration.
System Checklist & Troubleshooting
The fol low ing check list and trou ble shoot ing tips will as sure that you have in stalled the In
telliGuard 7000 cor rectly. If the sys tem does
not re act as noted, fol low the trou ble shoot ing tip(s) de noted with a black box be low that it em, then re peat the step. Each suc ces sive
step re quires that the pre vious step has been com pleted as in di cated.
The CliffNet Wizard simplifies the troubleshooting process by providing system diagnostic informati on in a graphical format. All
system settings are provided at-a-glance, and adjustments to the system settings can be made with a click of a mouse. This reduces
the amount of time required for performing the following tests.
Step 1.
Re- enable the cour tesy lights.
In step 1 of the Important Information sec tion in this binder, the in te rior cour tesy lights were disabled. You must now re-enable
the courtesy lights by re placing the fuse you re moved or re set the cour tesy light switch back t o its nor mal “DOOR” po si tion bef ore
pro ceed ing.