Eight Event TotalRecall (Continued)
Num ber of LED flashes be tween pauses Trig ger/sen sor in di ca tion
2 flashes Dual-Zone Piezo Sensor
3 flashes Optional Sensor
4 flashes Door Trigger
5 flashes 0Trunk Trigger
6 flashes Hood Trigger
7 flashes
An attempt was made to turn on the
ignition or start the engine while the system was armed
8 flashes
More than three consecutive incorrect
valet codes were entered while the system was in BlackJax mode
9 flashes BlackJax
10 flashes System Power Interruption
5.If a sensor is often activated, decrease that sensor’s sensitivity (or reposition the sensor, if ne cessary). If a certain trigger is often
activated, check pin switch operation, verify that the pin switch is not exposed to moisture and ch eck the trigger wire for possible
shorting.
Programmable Features
IntelliGuard 7000 comes from the factory with its features preprogrammed as noted in bold text in the tables on pages 10 and 11.
Some features can be programmed by the installer or the user, others can only be programmed only by the installer.
Using the CliffNet Wizard Pro
The CliffNet Wizard Pro provides an intuitive access to all installer and user-programmable feature
s through a user-friendly, graphical
user interface. Because CliffNet Wizard Pro is Windows™-compatible, most operations can be accomp lished by simply pointing and
clicking a mouse. CliffNet Wizard Pro totally eliminates complicated programming charts and length y button pressing sequences.
Please refer to the CliffNet Wizard Pro User’s Guide for more programming information if you are using the CliffNet Wizard Pro.
Otherwise, for manual programming refer to the tables provided in the following sections.
Programming the User-Selectable Features
1.Write down the column (across) number and row (down) number of the feature(s) you wish to program.
2. Turn the ignition to the “ON” position or start the engine.
3.Enter the factory preset valet/programming code of “2” by pressing the PlainView 2 Switch’s ✱ button two times, then press the
unmarked button.
4.After entering the code, press and hold the ✱ for about 3 seconds until you hear one siren chirp and the LED turns on to
acknowledge program mode entry. The IntelliGuard 7000 is now in the “Feature Select” position for U
ser-Programmable Features.
5.Select the feature column: Press the unmarked button the same number of times as the column number. Pause. You will then hear
the same number of chirps as the column number you have selected, audibly confirming your selection .
6.Within five seconds, select the feature row: Press the ✱
button the same number of times as the feature’s row number. You’ll hear a
chirp each time you press the unmarked side to help you count.
7.If there is a NOTE for the selected feature, perform the actions noted.
8. Pause. You will hear either one or two chirps: two chirps = ON, one chirp = OFF.
9.You can select another feature, or you can exit program mode:
a. To select another feature in that same column, repeat step 6 within the next five seconds (after fi ve seconds, three chirps
indicate that the IntelliGuard 7000 is now back in the “ Feature Select” position).
b. To select a different feature column, repeat step 5.
c. To exit program mode, turn the ignition off (you’ll hear three chirps and the LED will turn off to indicate exit of program
mode), or wait 60 seconds and the IntelliGuard 7000 will automatically exit program mode.