DE3_p01.
DE3_p02.
DE3_p03.fm Page 3 Saturday, January 10, 2015 2:05 AM Selection Information Miniature Circuit Breakers Class 500, 600 Multi 9™ Circuit Breakers and Supplementary Protectors EDB Circuit Breakers Plug-on — — — — — — — — Bolt-on — QOM1-VH QOM2-VH — — EDB EGB EJB QOU — — CSA C22.2 No. 5/UL 489 C60 CSA C22.2 No. 235/UL1077 C60 — — — 2 2 Unit Mount Current Range 15–70 15–125$ 2, 3 15–125$ 1 15–70 2, 3 15–125$ 1 15–70 2, 3 0.5–40 1 0.5–40 2 1–63 1 1–63 3,4 0.
DE3_p04.
DE3_p05.
DE3_p06.
DE3_p07.
DE3_p08.
DE3_p09.fm Page 9 Saturday, January 10, 2015 2:11 AM Selection Information Molded Case Circuit Breaker Class 500, 600, 800 400 A L-Frame Circuit Breaker Type Q4 LA LH Number of Poles 2, 3 2, 3 2, 3 250–400 125–400 125–400 Current Range 25 42 65 — 30 35 480 Vac — 30 35 600Y/347 Vac — 22 25 600 Vac — 22 25 250 Vdc — 10 50 500 Vdca — — 20 240 Vac — — — 415 Vac — 20/5 20/5 CCC — — — Fed.
DE3_p10.fm Page 10 Saturday, January 10, 2015 2:11 AM QO™ and QOU Miniature Circuit Breakers QO™ Miniature Circuit Breakers Class 730, 731, 733 / Refer to Catalog 0730CT9801 QO™ miniature circuit breakers are plug-on products for use in QO load centers, NQOD panelboards, NQOD OEM interiors or Speed-D™ switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD panelboards or interiors.
DE3_p011.fm Page 11 Saturday, January 10, 2015 2:12 AM QO™ and QOU Miniature Circuit Breakers QO™ Miniature Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog 0730CT9801 QO Arc Fault Circuit 1P 120/240 Vac 1P 120 Vac 2P QO-GFI Cat. No. QO115CAFI QO120CAFI 15 A 20 A Combination Arc-fault Interrupter 1P QO-GFI 1P 120 Vac 10 k AIR 22 k AIR Ampere Rating 1 Space Required 1 Space Required Circuit Breaker Type Cat. No.
DE3_p012.
DE3_p013.fm Page 13 Saturday, January 10, 2015 2:13 AM QO™ and QOU Miniature Circuit Breakers QO™ and Multi 9™ Mounting Bases Class 652 / Catalogs 0730CT9801, 0860CT0201 QO OEM Mounting Bases Main Lug Rating 1P Spaces Max. No. 1P Mounting Bases Main Wire Size AWG/kcmil Cat. No. QO Plug-On Mounting Bases—For unit mounting QO, QO-GFI, QO-AFI and QO-EPD circuit breakers 1Ø2W 240 Vac Max.
DE3_p014.fm Page 14 Saturday, January 10, 2015 2:13 AM QO™ and QOU Miniature Circuit Breakers Class 720 / Refer to Catalog 0730CT9801 QOU Miniature Circuit Breakers Low Ampere QOU Miniature Circuit Breakers QOU unit mount miniature circuit breakers (cable-in/cable-out) are ideal for OEM applications. They have the Square D™ circuit breaker’s unique Visi-Trip™ feature and can be DIN rail-mounted or surface- or flush-mounted using mounting feet.
DE3_p015.fm Page 15 Saturday, January 10, 2015 2:14 AM QO™ and QOU Miniature Circuit Breakers QOU Accessories Class 720 / Refer to Catalog 0730CT9801 Cat. No. Factory-installed ring tongue terminal, 10–32 screw, for 1P, 2P, 3P QOU, 10–60 A Hex drive 5/32 in.
DE3_p016.fm Page 16 Saturday, January 10, 2015 2:14 AM Multi 9™ Miniature Circuit Breakers CSA C22.2 No. 5/UL 489 C60 Miniature Circuit Breakers Class 860 / Refer to Catalog 0860CT0201 Multi 9 C60 CSA C22.2 No.
DE3_p017.fm Page 17 Saturday, January 10, 2015 2:15 AM Multi 9™ Miniature Circuit Breakers Class 860 / Refer to Catalog 0860CT0201 CSA C22.2 No. 5/UL 489 C60 480 Vac C60 Miniature Circuit Breakers Multi 9 C60 CSA C22.2 No.5/UL 489 Listed 480V Miniature Circuit Breakers • • • • UL 489 Listed, CSA C22.2 No. 5.1; Also IEC 60947-2; CE marked 480Y/277 Vac @ 10 kA (2P and 3P), 277 Vac @ 10 kA (1P) 0.
DE3_p018.fm Page 18 Saturday, January 10, 2015 2:15 AM Multi 9™ Miniature Circuit Breakers UL1077 C60H Circuit Breakers Class 860 / Refer to Catalog 0860CT0201 Multi 9 C60H-DC UL 1077 Recognized (not CSA certified) Supplementary Protectors (250 and 500 Vdc) The C60H-DC supplementary protectors are used in direct current circuits (industrial control and automation, transport, renewable energy, etc.). They provide overcurrent protection within appliances or electrical equipment.
DE3_p019.fm Page 19 Saturday, January 10, 2015 2:16 AM Class 685, 690, 730, 912, 950 / Refer to Catalog 0730CT9801 Multi 9™ Miniature Circuit Breakers CSA C22.2 No. 235/UL 1077 C60 Supplementary Protectors Intended for use within equipment where branch circuit protection is already provided or not needed • • • • • Range from 0.
DE3_p020.fm Page 20 Saturday, January 10, 2015 2:16 AM Multi 9™ Miniature Circuit Breakers C60 Accessories Class 860 / Refer to Catalog 0860CT0201 Electrical Accessories for C60 Circuit Breakers and Supplementary Protectors Possible Combinations Mounted to the left of the circuit breaker with a maximum width of 54 mm.
DE3_p021.fm Page 21 Saturday, January 10, 2015 2:23 AM PowerPact™ Molded Case Circuit Breakers PowerPact Family Class 611 The PowerPact Advantage • Proven Performance: Industry-leading circuit breaker innovation and protection for heavy-duty commercial and industrial applications. Smart: Integrated metering options provide a cost-effective solution to reduce energy consumption, optimize energy costs, and improve energy availablility for your facilities.
DE3_p022.
DE3_p023.
DE3_p024.
DE3_p025.
DE3_p026.fm Page 26 Saturday, January 10, 2015 2:26 AM PowerPact™ Circuit Breakers M-Frame Circuit Breakers Class 612 / Refer to Catalog 0612CT0101 Frame—800 A, Standard Rated, Basic Electronic Trip System Type ET 1.
DE3_p027.fm Page 27 Saturday, January 10, 2015 2:26 AM PowerPact™ Circuit Breakers P-Frame Circuit Breakers Class 612 / Refer to Catalog 0612CT0101 P Frame - 1200A, (600 Vac, 50/60 Hz) 3P a Circuit Breaker with Electronic Trip Unit Trip Unit Fixed long-time, Adjustable Instantaneous ET1.0I LI 3.0 Micrologic Interchangeable Standard Trip Unit LSI LI Micrologic Interchangeable Ammeter Trip Unit LSI LSIG LSI 5.0 3.0A 5.0A 6.0A 5.0P Micrologic Interchangeable Power Trip Unit LSIG LSI 6.
DE3_p028.
DE3_p029.fm Page 29 Saturday, January 10, 2015 2:27 AM Motor Circuit Protectors and Motor Protector Circuit Breakers PowerPact™ H- and J-Frame Class 611 / Refer to Catalog 0611CT1001 PowerPact H- and J-frame electronic Motor Circuit Protectors (MCP) are magnetic-only instantaneous-trip circuit breakers.
DE3_p030.
DE3_p031.fm Page 31 Saturday, January 10, 2015 2:29 AM Motor Protectors Motor Circuit Protectors and Motor Protector Circuit Breakers Class 580, 585, 680, 685 Motor Circuit Protectors Mag-Gard™ Motor Circuit Protectors (MCP) are instantaneous-trip magnetic-only circuit breakers. They have a single adjustment which simultaneously sets the magnetic trip level of each individual pole.
DE3_p032.fm Page 32 Saturday, January 10, 2015 2:29 AM Motor Circuit Protectors H-, J-, and L-Frame MCP Selection Class 680 Adjustable Instantaneous Trip Circuit Breakers For Single Motor Circuit Protection Adjustable Instantaneous trip circuit breakers are intended for use in combination with motor starters with overload relays for the protection of motor circuits from short circuits. Other specific applications include rectifiers and resistance welders.
DE3_p033.fm Page 33 Saturday, January 10, 2015 2:29 AM Motor Circuit Protectors 7-1/2 30 10 25 3 10 7-1/2 7--1/2 15 10 40 50 20 15 5 10 7-1/2 60 20 50 25 20 10 60 75 25 30 7-1/2 25 30 75 100 10 40 30 40 100 125 50 40 150 50 60 125 50 60 150 75 200 75 200 250 100 100 300 250 125 350 125 150 300 400 150 350 500 400 200 200 500 250 01/15 5 15 29.0 A 32.0 A 32.2 A 34.0 A 38.0 A 40.0 A 41.0 A 42.0 A 46.0 A 48.3 A 50.0 A 52.0 A 54.0 A 55.0 A 56.0 A 57.5 A 58.0 A 62.0 A 62.1 A 65.0 A 68.0 A 72.
DE3_p034.fm Page 34 Saturday, January 10, 2015 2:30 AM Automatic Switches Class 600 / Refer to Catalogs 0611CT1001, 0612CT0101 Automatic molded case switches open instantaneously at a factory preset magnetic trip point, calibrated to protect only the molded case switch itself, when it is subjected to high fault currents. The trip point is nonadjustable and provides no overload or low level fault protection.
DE3_p035.fm Page 35 Saturday, January 10, 2015 2:30 AM 500 Vdc Circuit Breakers Class 500, 600 CSA/UL Listed 500 Vdc Circuit Breakers The CSA/UL Listed thermal-magnetic molded case circuit breakers shown below are specifically designed for use on ungrounded dc systems having a maximum short-circuit voltage of 500 Vdc or a maximum floating (unloaded) voltage of 600 Vdc. The circuit breakers are suitable for use only with UPS (uninterruptable power supplies) and ungrounded systems.
DE3_p036.fm Page 36 Saturday, January 10, 2015 2:30 AM 500 Vdc Circuit Breakers CSA/UL Listed 500 Vdc NW Circuit Breakers Class 0613DC / Refer to catalog 0613CT0501 DE3 CIRCUIT BREAKERS CSA/UL Listed Masterpact NW DC circuit breakers are for use on ungrounded systems rated 500 Vdc (600 Vdc unloaded) or less. IEC Rated circuit breakers are for use on ungrounded, grounded middle point, or grounded negative systems. Please refer to catalog 0613CT0501 for details.
DE3_p037.fm Page 37 Saturday, January 10, 2015 2:31 AM Mission Critical Circuit Breakers Selective Coordination Designed for selectively coordinated systems, mission critical circuit breakers maximize continuity of the electrical service by allowing the branch circuit breaker to clear the fault.
DE3_p038.fm Page 38 Saturday, January 10, 2015 2:31 AM Mission Critical Circuit Breakers Selective Coordination LA Mission Critical Circuit Breakers The LA High Magnetic Withstand MC Circuit Breakers are designed to trip at a higher magnetic trip level (18–20 times handle rating) than typical molded case circuit breakers (MCCBs) (which trip at 5–10 times the handle rating). The high magnetic withstand value of these LA circuit breakers allow the downstream branch circuit breaker to clear the fault.
DE3_p039.fm Page 39 Saturday, January 10, 2015 2:32 AM PowerPact™ Circuit Breaker Accessories Electrical Accessories Class 0611, 612 / Refer to Catalogs 0611CT1001, 0612CT0101 Electrical Accessories Auxiliary and Alarm Switches (OF, SD, SDE) Provides circuit breaker contact status. Standard Min Load = 10mA with 24V Note:The location of the accessory in the circuit breaker determines its function.
DE3_p040.fm Page 40 Saturday, January 10, 2015 2:32 AM PowerPact™ Circuit Breaker Accessories Motor Operators and Rotary Handles Class 0611, 612 / Refer to Catalogs 0611CT1001, 0612CT0101 Motor Operators for H-, J-, and L-Frame Circuit Breakers Description AC Standard motor for electrically-operated circuit breakersb DC Communicating motor for electrically-operated circuit breakersc Motor Operator AC Field--Installable Kit H-Framea J-Frame L-Frame 600 A ML MA Cat. No. S29440 S29433 Cat. No.
DE3_p041.fm Page 41 Saturday, January 10, 2015 2:41 AM Class 0611, 612 / Refer to Catalogs 0611CT1001, 0612CT0101 PowerPact™ Circuit Breaker Accessories Locks, Installation Accessories, and Rear Connections Locks, Interlocking Device Description FieldInstalled Cat. No.
DE3_p042.
DE3_p043.
DE3_p044.fm Page 44 Saturday, January 10, 2015 2:43 AM PowerPact™ Circuit Breaker Accessories Class 0611, 612 / Refer to Catalogs 0611CT1001, 0612CT0101 Terminal Nuts, Terminal Pads, Terminal Shields and Accessories Terminal Nuts for Bus Bar Connection of H-Frame and J-Frame Circuit Breakers Description Terminal Nut Insert Frame Tap Cat. No.
DE3_p045.fm Page 45 Saturday, January 10, 2015 2:43 AM PowerPact™ Circuit Breaker Accessories Plug-In and Drawout Mountings Class 611, 612 / Refer to Catalogs 0611CT1001, 0612CT0101 Plug-In and Drawout Mountings for H- and J-Frame Circuit Breakers (3P or 2P in a 3P module) Factory Installed Cat. No.
DE3_p046.fm Page 46 Saturday, January 10, 2015 2:44 AM Micrologic™ Electronic Trip Units Class 611 / Refer to Catalog 0611CT1001 Micrologic Trip Unitsf for PowerPact H-, J-, and L-Frame Circuit breakers x– Standard Feature PowerPact™ H-, J-, and L-Frame Micrologic™ Trip Units Micrologic Standard Trip Unit DE3 CIRCUIT BREAKERS Micrologic Ammeter and Energy Trip Unit PowerPact™ H-, J-, and L-frame molded case circuit breakers may be specified with any of the following Micrologic Electronic Trip Units.
DE3_p047.fm Page 47 Saturday, January 10, 2015 2:45 AM Micrologic™ Electronic Trip Units Class 612 / Refer to Catalog 0612CT0101 Powerpact P- and R-Frame, and Masterpact Micrologic Electronic Trip Units Each adjustment times the sensor rating (lr X In) of the circuit breaker sets the long-time pickup value of the circuit breaker. Long-time Pickup Settings Long-time Pickup Settings .90 .95 .95 .95 .95 .98 .80 .62 .80 .88 .83 .93 .93 .96 .78 .
DE3_p048.fm Page 48 Saturday, January 10, 2015 2:45 AM Micrologic™ Electronic Trip Unit Micrologic™ Trip Unit Accessories Class 612 / Refer to Catalog 0612CT0101 Trip Unit Accessories Adjustable rating plug "A" is installed as standard on all Micrologic trip unit orders. However, an alternative selection may be specified from the "Assembled" table below, and factory-installed with your trip unit order at no additional charge.
DE3_p049.fm Page 49 Saturday, January 10, 2015 2:46 AM Micrologic™ Electronic Trip Unit Micrologic™ Trip Unit Accessories Class 0611, 612 / Refer to Catalogs 0611CT1001, 0612CT0101 Trip Unit Field-Installable Accessories for P- and R-Frame Circuit Breakers Factory-Installed Description Field-Installable Kit Cat. No. P-Frame Cat. No.
DE3_p050.fm Page 50 Saturday, January 10, 2015 2:46 AM Masterpact™ Universal Power Circuit Breakers Masterpact™ NT/NW Circuit Breakers Class 613 / Refer to Catalog 0613CT0001 The Masterpact universal power circuit breaker offers a family of circuit protection products meeting the most common world standards, ANSI, CSA/UL and IEC. The basic design platform for each is common. The final result is CSA/UL, ANSI and IEC circuit breakers with the same basic external dimensions, features and accessories.
DE3_p051.
DE3_p052.fm Page 52 Saturday, January 10, 2015 2:35 AM Ground-Fault Protection Vigirex™ Ground-Fault Relay System Class 931, 840, 960 Vigirex™ Ground-Fault Relay System The Vigirex ground-fault relays, with associated sensors (current transformers), measure the residual current in an electrical installation to detect levels which may be damaging. When used for protection, they cause an associated circuit breaker or switch to interrupt the supply of power to the protected system.
DE3_p053.fm Page 53 Saturday, January 10, 2015 2:35 AM Ground-Fault Protection Equipment Add-On Ground-Fault and Earth-Leakage Modules Class 931, 940, 960 The Micrologic ground-fault module (GFM) is a CSA certified and UL Listed circuit breaker accessory which protects equipment from damage caused by ground faults. It is an add-on module which, when connected to a PowerPact H- or J-frame thermal-magnetic circuit breaker only, provides ground-fault sensing and ground-fault relay functions.
DE3_p054.fm Page 54 Saturday, January 10, 2015 2:36 AM Dimensions and Shipping Weights Miniature and Molded Case Circuit Breakers Figure 2 Figure 1 B E D C A G B E A G E B Fig. No. A B C D E F G 1 1 0.75 3.00a 2.31 2.91 2.25 ... 0.59 2 2 1.50 3.00a 2.31 2.91 2.25 ... 1.34 3 3 2.25 3.00a 2.31 2.91 2.25 ... 2.09 2 2 3.0 5.72 2.53 4.90 3.78 ... 2.85 3 3 4.50 5.72 2.53 4.90 3.78 ... 4.35 1 4 0.75 4.12b 2.31 2.91 2.25 ... 0.59 2 5 1.50 4.
DE3_P055.fm Page 55 Saturday, January 10, 2015 2:37 AM Dimensions and Shipping Weights Molded Case Circuit Breakers Figure 25 Figure 26 B B G F A HD, HG, HJ, HL, HR, JD, JG, JJ, JL, JR, LG, LJ, LL, and LR Circuit Breakers E Circuit Breaker No. of Cat. No. Poles Fig. No. A Prefix 2* 25 6.40 HD, HG, HJ, HL, HR 3 26 6.40 JD, JG, JJ, 3 27 7.52 JL, JR LG, LJ, LL, LR 3 28 13.38 F A D E C Dimensions — Inches B C D E F G 2.74 4.12 2.87 2.87 4.36 4.36 0.74 0.74 4.92 4.92 — 1.38 4.12 2.
DE3_p056.fm Page 56 Friday, January 23, 2015 12:16 AM Circuit Breaker Enclosures Enclosures Class 610 Circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service entrance equipment, except as footnoted. The short circuit current rating of an enclosed circuit breaker is equal to the interrupting rating at the supply voltage marked on the circuit breaker installed, except as footnoted. Exceptions and restrictions are footnoted.
DE3_p057.fm Page 57 Saturday, January 10, 2015 2:37 AM Circuit Breaker Enclosures Enclosed Circuit Breaker Special Applications Class 610 Circuit Breaker Catalogue Number Prefix FAL, FHL▲ ✸ ■ ▼ ▲ ➀ Ampere Rating 15-60 Number of Poles 1, 2, 3 Type 7 ✸ Cast Aluminum Enclosure Catalogue No. FA060X▼ FA100X▼ NEMA Type 7 – Indoor Hazardous Locations – Class I, Groups C and/or D, Divisions 1 or 2. NEMA Type 9 – Indoor Hazardous Locations – Class II, Groups E and/or G, Class III, Divisions 1 or 2.
DE3_p058.fm Page 58 Friday, January 23, 2015 12:20 AM Circuit Breaker Enclosures Enclosure Accessories and Dimensions Class 610 Accessories Insulated Groundable Neutral Assembly Circuit Breaker Neutral Assembly For Use With Ampere Rating NEMA 1 & 3R 100 100 HDL,HGL,HJL,HLL HDL,HGL,HJL,HLL JDL,JGL,JJL,JLL LAL, LHL, Q4L 15–100 125-150 150–250 400 SN100FA SN400LA SN400LA 400SN LDL, LGL, LJL, LLL, LRL 250-400 — LDL, LGL, LJL, LLL, LRL 250-600 — Cat. No.
DE3_p059.fm Page 59 Saturday, January 10, 2015 2:38 AM Photovoltaic Circuit Breakers and Switches 600 Vdc and 1000 Vdc PV Circuit Breakers and Switches Class 611 / Refer to Catalog 0611CT1302 The UL listed thermal-magnetic molded case circuit breakers and switches shown below are specifically designed for use in PV applications, rated at 50°C, offering grounded or ungrounded configurations. The products are fully tested and calibrated under the PV UL489B standard.
DE3_p060.fm Page 60 Friday, January 23, 2015 12:22 AM Photovoltaic Circuit Breakers and Switches Factory Installed Accessories Class 611 / Refer to Catalog 0611CT1302 S29450 2 3A/3B Standarda AC S29450 3 1A/1B Low-Level (Gold) AE S29452 1 2A/2B Low-Level (Gold) AF S29452 2 3A/3B Low-Level (Gold)a AG S29452 3 a U-Frame only. Alarm/Overcurrent Trip Switches Suffix Switch Kit No. Kit Qty.
DE3_p061.fm Page 61 Saturday, January 10, 2015 2:39 AM Photovoltaic Circuit Breakers and Switches T-Frame Dimensions and Shipping Weights Class 611 / Refer to Catalog 0611CT1302 PV T-Frame Circuit Breaker and Switches Dimensions A2 7.40 188 in mm A3 11.42 290 B1 4.13 105 B2 5.51 140 C2 3.39 86 C3 4.
DE3_p062.fm Page 62 Saturday, January 10, 2015 2:40 AM Photovoltaic Circuit Breakers and Switches U-Frame |Dimensions and Shipping Weights Class 611 / Refer to Catalog 0611CT1302 PV U-Frame Circuit Breaker and Switches Dimensions A2 11.2 285 A3 15.7 400 A4 19.1 484 B1 5.5 140 B2 7.2 183 C2 4.3 110 C3 6.
DE3_p063.fm Page 63 Saturday, January 10, 2015 2:40 AM Moulded Case Circuit Breaker F-Frame Thermal-Magnetic Circuit Breakers Thermal-magnetic moulded case circuit breakers shown here are permanent trip CSA certified, UL listed, IEC rated. For I-LINE moulded case circuit breakers, see Section DE-5. Ampere Rating AC Magnetic Trip Settings Amperes One Pole Catalogue No. Two Pole Price Catalogue No. Three Pole Price Catalogue No.
DE3_p064.fm Page 64 Saturday, January 10, 2015 2:34 AM Moulded Case Circuit Breakers Q4L - LAL - LHL CSA Certified Interrupting Rating RMS Symmetrical Amperes Breaker Cat. No. Prefix System Voltage AC DC 240 480 600 125 250 Q4L LAL LHL 25k 42k 65k 30k 35k 22k 25k 10k 50k 10k 50k Enclosures - DE3-56 Dimensions - DE3-54 Ampere Rating AC Magnetic Trip Settings Amperes Two Pole Catalogue No. Three Pole Price Catalogue No.
DE3_p065.fm Page 65 Friday, January 23, 2015 12:24 AM Moulded Case Circuit Breakers CDP Breaker Cross to Square D CDP Connector Kits The CDP connector kits are used to install Square D breakers into existing Federal Pioneer CDP panels and Switchboard distribution interiors that originally used branch breakers from the Horizon family.