Specifications

Web-based management
RS2-4R
Release
1.0
03/04
5.3
System
137
U Auto Configuration Adapter (ACA)
The ACA is a device for storing the configuration data of a MICE,
RS2-../.., RS2-16M, RS2-4R or MACH 3000 switch. In the case of a
switch failure, the ACA enables a very simple configuration data transfer
by means of a substitute switch of the same type.
Storing the current configuration data in the ACA:
You can transfer the current switch configuration onto the ACA and the
flash memory with "Save local configuration".
First Select the "Local"
setting in the "Save" field.
Transferring the configuration data from the ACA:
When you restart, the switch assumes the configuration data of the ACA
and saves them permanently into the flash memory.
Which data the
switch takes from the ACA depends on the setting in the restart configu
-
ration (see Table 9 on page 137).
If the connected ACA does not contain any valid data, for example a new
ACA, the switch then loads the data from the flash memory.
Setting Result
Local The switch takes all the data from the ACA
from URL The switch takes the IP parameters from the
ACA and the other data from the URL
defaults The switch takes the IP parameters from the
ACA and sets the other parameters to the
default setting
Table 9: Data transfer from ACA after restart