Specifications

Appendix
244
Technical Data
RS2-4R
Release
1.0
03/04
EMC interference immunity
EN 61000-4-2 electrostatic discharge
contact discharge:
test level 3 (6 kV)
air discharge:
test level 3 (8 kV)
EN 61000-4-3 elektromagnetic field
test level 3
(10 V/m; 80 - 2000 MHz)
EN 61000-4-4 fast transients (burst)
test level 3
(2 kV power line, 1 kV data line)
EN 61000-4-5 surge voltage
power line
s y m m e t r i s c h : t e s t l e v e l 2 ( 1 k V )
unsymmetrisch: test level 3 (2kV);
data Line: test level 2 (1kV)
EN 61000-4-6 cable-based RF faults: test level 3
10 V (150 kHz - 80 MHz)
EMC emitted immunity
EN 55022 Class A
FCC 47 CFR Part 15 Class A
Germanischer Lloyd Rules for Classification and
Construction VI - 7 - 3 Part 1, Ed. 2001
Stability
Vibration IEC 60068-2-6 Test FC, testing level
in line with IEC 61131-2 and
Germanischer Lloyd Guidelines for
the Performance of Type Tests Part 1
Shock IEC 60068-2-27 Test Ea, testing level
in line with IEC 61131-2
Network size TX port 10BASE-T/100BASE-TX/1000BASE-TX
Length of a TP segment 100 m (328 ft) max.