Specifications
Installation and startup procedure
RS2-4R
Release
1.0
03/04
3.2
Device installation
37
3.2 Device installation
3.2.1 Controls
U DIP switch
With the -pin DIP switch on the front panel of the RS2-4R
D the RM functionality (Redundancy Manager) can be switched on or off
with the RM switch
if the HIPER-Ring function is switched on. State on
delivery: switch position 0 (Off), i.e. RM function not active (see
“Redundant ring structure – HIPER-Ring” on page 114).
D the HIPER-Ring fuctionality can be switched on or off with the RING
switch. State on delivery: switch position 0 (Off), i.e. HIPER-Ring
function not active.
Fig. 2: 2-pin DIP switchr
V Check whether the switch default settings match your requirements.
RING RM Port 3 and Port 4 Redundancy Manager
0 - TP port: Autonegotiation,
FX port: 100 Mbit/s full duplex
off
1 0 Ring port: 100 Mbit/s full duplex off
1 1 Ring port: 100 Mbit/s full duplex on
Table 2: DIP switch function
01
RING
RM
HIPER-Ring
Redundanz Manager