Specifications

Installation and startup procedure
54
3.4
Basic settings
RS2-4R
Release
1.0
03/04
The RS2-4R should be labeled to prevent confusion during subsequent
installation.
V Connect a VT 100 terminal or a PC with terminal emulation to the RJ11
socket (V.24).
Data transfer parameters:
Speed: 9,600 baud
Data: 8 bit
Parity: none
Stopbit: 1 bit
Handshake: off
Note: The transmission rate can be changed in the system monitor (see “3
Change Baudrate” on page 78).
V Once the RS2-4R has been installed, start it by connecting the power
supply. The operating system is loaded.
You start the user interface starts by pressing a key (see “Opening the
user interface” on page 211).
V Enter the password you assigned (pay attention to lower and upper case
letters) and press the enter key.
Note: On delivery the password is set to private.
V Enter the IP addresses as described in “System parameters” on page 213
and in accordance with the following guidelines.
U Local IP address (local ip-address)
On delivery, the local IP address of the RS2-4R is 0.0.0.0.
U IP address of the gateway (gateway ip-address)
This entry is only needed if the and the management station/tftp server
are located in different subnetworks (see
“Example of how the network
mask is used” on page 51).
Enter the IP address of the gateway between the subnetwork with the
and the path to the management station.
The default setting of the IP address is 0.0.0.0.