CP Fault Indications
Yellow LED
Conditions
Fault Condition:
Green LED ON Then OFF, Red LED ON
ON
OFF
OFF
OFF
OFF
1. Nonvolatile Memory write test failed before the PeerWay boot
procedure was performed. The Nonvolatile Memory card
should be replaced.
ON
OFF
OFF
ON
OFF
2. No Nonvolatile Memory card is present or the Nonvolatile
Memory card switch is in the DISABLE position.
ON
OFF
ON
OFF
OFF
3. Checksum i nvalid after load. If the problem persists, a
nonvolatile memory reload from disk may be necessary.
ON
OFF
ON
ON
OFF
4. Uncorrectable error detected in CP card communications.
Replace the CP card.
ON
ON
OFF
OFF
OFF
5. Nonvolatile memory initialize failed. Nonvolatile Memory card
problem. See Chapter 10, Troubleshooting.
ON
ON
OFF
ON
OFF
6. Nonvolatile memory table c hecksum bad. Nonvolatile
Memory card problem. See Chapter 10, Troubleshooting.
ON
ON
ON
OFF
OFF
7. No program image stored in the nonvolatile memory. See
Chapter 10, Troubleshooting.