Specifications
SQ: 6-14
RS3: Service Quick Reference Guide
ControlFiles
CP Fault Indications (continued)
Yellow LED
Conditions
Fault Condition:
Green LED ON Then OFF, Red LED ON
ON
ON
ON
ON
OFF
8. Nonvolatile Memory card hardware error on read. If the
Nonvolatile Memory card was enabled, the card should be
replaced.
ON
OFF
OFF
ON
OFF
9. No Nonvolatile Memory card is present or the Nonvolatile
Memory card switch is set at DISABLE.
CP-IV+ Jumper Positions
Jumper
Position Function
HD3 to HD6 1--2 Factory set -- do not move
HD7
MPC II or
MPC5
(1--2)
Working with MPC II or MPC5 Controller Process o rs
only (Factory Setting)
OTHER
(2--3)
Working with MPC I Controll er Processors
or a mix of MPC I and MPC II
CP-IV Jumper Position
Jumper
Position Function
HD3 to HD6 1--2 Factory s et -- do not move
CP-II Software Jumper Positions
Software
Jumper HD8 Jumper HD16
$$CPBATxx 2--3 2--3
$$CPxx V9 1--2 1--2
$$CPMAXXxx V9 and above
$$CPxx V11 and above
2--3 1--2