Specifications

SQ: 1-24
RS3: Service Quick Reference Guide
Troubleshooting
Memory View Screen
The Memory View screen has been added to allow you to view the
contents of a memory dump file or the current contents of memory. The
screen is only available with 68020 pixel consoles.
-
To read current memory data from a node:
1. Call up the Memory View screen.
MV [ENTER]
2. If you want to look at a node other than the one you are at,
change the “Node” field entry.
-
To read memory data from a file:
1. Call up the Memory View screen.
MV [ENTER]
2. Cursor to the “Memory” field and press [ENTER]. The field
changes to “File”.
3. Enter the “Volume”, “File Type”, and “Filename” of the file that
contains the memory data.
4. Cursor to the “Read” field and press [ENTER].
5. To access other screens to see more memory data:
[PAGE AHEAD] and [PAGE BACK]
Memory View Screen Field Description
Field
Description
Addr
Specifies the starting address of the memory data
displayed on the screen.
Decimal/Hex
Specifies that addresses are shown in decimal or
hexadecimal.
To change this field, press [ENTER].
File/Memory
Specifies that the memory data is being read from a file or
directly from the node.
You can change this field by pressing [ENTER].
File Type
Specifies the type of folder that contains the file you want
to view. For memory dumps, the type should be “Log File”.
(continued on next page)